22
E
7. Electrical work
7.3. Remote controller
1) Installing procedures
(2) Seal the service entrance for the remote controller cord with putty
to prevent possible invasion of dew drops, water, cockroaches or
worms.
A
For installation in the switch box:
•
When the remote controller is installed in the switch box, seal the junc-
tion between the switch box and the conduit tube with putty.
B
For direct installation on the wall select one of the following :
•
Prepare a hole through the wall to pass the remote controller cord (in
order to run the remote controller cord from the back), then seal the
hole with putty.
•
Run the remote controller cord through the cut-out upper case, then
seal the cut-out notch with putty similarly as above.
B-1. To lead the remote controller cord from the back of the control-
ler:
B-2. To run the remote controller cord through the upper portion:
C
Wall
D
Conduit
E
Lock nut
F
Bushing
G
Switch box
H
Remote controller cord
I
Seal with putty.
7.3. Remote controller
1) Installing procedures
(3) Install the lower case in the switch box or on the wall.
A
For installation in the switch box
C
Switch box for two pieces
D
Remote controller cord
E
Cross-recessed, pan-head screw
F
Connect to the connector CN1 on the upper case
G
Seal the remote controller cord service entrance with putty
B
For direct installation on the wall
H
Wood screw
Caution:
Do not over-tighten the screws to possible deformed or broken lower
case.
Note:
•
Select a flat place for installation.
•
Be sure to use two or more locations for securing of the remote
controller in the switch box or on the wall.
F
A
H
C
D
E
G
I
B
I
B-1.
B-2.
I
E
D
C
A
G
F
H
D
B
F