 FOR YOUR SAFETY 

  This product has been manufactured as a general-purpose product for general industry 

applications, etc. The product is not designed or manufactured to be used in equipment or 
systems in situations that can affect or endanger human life. 

  When considering this product for operation in special applications such as machinery or 

systems used in passenger transportation, atomic power, electric power, aerospace, or medical 
applications, please contact your nearest Mitsubishi sales representative. 

  Although this product was manufactured under conditions of strict quality control, the product 

shall be systematically provided with backup and fail-safe functions when it is used in facilities 
where breakdowns of the product are likely to cause a serious accident or damage. 

 

 

1-13-5 Kudankita, Chiyoda-ku, Tokyo, Japan    102-8404 
Our website URL: 

http://www.mee.co.jp/

 

 

 

50D-FA9010-094-A  

Specifications subject to change without notice. 

 

Published in June 2015 

 

Содержание FA Goods FA-TH16YRA20SL

Страница 1: ...th this product only For programmable controller system safety precautions refer to the user s manual of the programmable controller used In this manual the safety precautions are classified into two levels WARNING and CAUTION WARNING Indicates that incorrect handling may cause hazardous conditions resulting in death or severe injury CAUTION Indicates that incorrect handling may cause hazardous co...

Страница 2: ...current or an overcurrent caused by a load short circuit flows for a long time it may cause smoke and fire To prevent this configure an external safety circuit such as a fuse Configure a circuit to turn on the programmable controller and then the external power supply If the external power supply is turned on first an accident may occur due to an incorrect output or malfunction Design Precautions ...

Страница 3: ...que range Undertightening can cause the product to drop short circuit or malfunction Overtightening can damage screws and or the product causing the product to drop short circuit or malfunction Be sure to shut off the external power supply for the system in all phases before installing or removing the product Failure to do so may damage the product or cause the product to malfunction or fail Do no...

Страница 4: ... so may cause a malfunction When disconnecting a cable from the product do not pull the cable itself For a cable with connector hold the connector and pull it out For a cable connected to a terminal block loosen the terminal block screws before removing the cable Failure to do so may result in a malfunction or damage to the product or cable Before connecting the cables check the type of interface ...

Страница 5: ...use of the product do not mount remove the module and the cable more than 50 times IEC 61131 2 compliant respectively Exceeding the limit of 50 times may cause malfunction Startup and maintenance of a control panel must be performed by qualified maintenance personnel with knowledge of protection against electric shock Lock the control panel so that only qualified maintenance personnel can operate ...

Страница 6: ...factures must issue an EC Declaration of Conformity and the products must bear a CE marking 1 Authorized representative in Europe The authorized representative in Europe is shown below Name Mitsubishi Electric Europe B V Address Gothaer strasse 8 40880 Ratingen Germany 2 How to use the FA Goods in compliance with the EMC and Low Voltage Directives For information on how to conform to the EMC and L...

Страница 7: ...ARY LOSS FOR YOUR SAFETY Modified English sentences SAFETY PRECAUTIONS EMC and Low Voltage Directives 1 INTRODUCTION 2 GENERAL SPECIFICATIONS 3 PERFORMANCE SPECIFICATIONS 7 INSTALLATION METHOD 10 APPLICABLE SOLDERLESS TERMINALS FOR YOUR SAFETY Japanese manual number 50D FA9010 068 This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licens...

Страница 8: ...tinuous vibration 5 to 8 4Hz 1 75mm 8 4 to 150Hz 4 9m s2 0 5G Shock resistance Compliant with JIS B 3502 and IEC61131 2 147m s2 15G 3 times each in X Y and Z directions Operating atmosphere No corrosive gas Operating altitude 1 2 000m or lower Installation location Inside the control panel Overvoltage category 2 II or lower Pollution level 3 2 or lower 1 Do not use or store the module under the at...

Страница 9: ...8lbf in UL standard conformity tightening torque 80N cm 7 08 lbf in Module mounting Mounting screws M4 35mm or greater Tightening torque range 78 to 118N cm 8 to 12kgf cm 7 to 10lbf in DIN rail Applicable DIN rail TH35 7 5Fe TH35 7 5Al IEC60715 compliant Weight About 390g 4 Evaluation for UL certification is conducted under resistance load conditions 3 2 Characteristics data of used relay 3 2 1 Ma...

Страница 10: ...e 4 FA CBL FM2LV Note 4 QH42P QX41Y41P Output side FA CBL FM2V Note 4 FA CBL FM2LV Note 4 MELSEC L Series connector type LY41NT1P LY42NT1P FA CBL FM2V Note 4 FA CBL FM2LV Note 4 MELSEC AnS Series connector type A1SY41P A1SY42P FA CBL FM2V Note 4 FA CBL FM2LV Note 4 A1SH42 A1SH42 S1 A1SH42P A1SH42P S1 Output side FA CBL FM2V Note 4 FA CBL FM2LV Note 4 CC Link connector type AJ65SBTCF1 32T AJ65BTC1 ...

Страница 11: ...11 6 MODULE MOUNTING ORIENTATION Horizontal mounting Vertical mounting Plane mounting ...

Страница 12: ...ck type PLC module 7 1 1 When a connection cable with terminal block is used Install the terminal block securely to the PLC module with mounting Insert the connector fully to connect it securely Programmable controller module QY40P Connection cable FA CBL TMV20 ...

Страница 13: ...able with loose wires is used Insert the connector fully to connect it securely Programmable controller module QY40P Wire the cable securely to the terminal block of PLC module Connection cable FA CBL M20 FA CBL YM20 ...

Страница 14: ...sed Install the connector securely to the PLC module with mounting screws Programmable controller module QY41P or others Insert the connector fully to connect it securely Connection cable FA CBL FM2V FA CBL FM2LV FA CBL FM2H FA CBL FM2LH Insert the connector fully to connect it securely ...

Страница 15: ...15 7 2 2 When 20P connector cable is used Insert the connector fully to connect it securely CC Link LT remote I O CL2Y16 TP1M1V Connection cable FA CBL MMH20 ...

Страница 16: ...16 8 EXTERNAL CONNECTION EXAMPLE 9 HOW TO DISMOUNT AND SET THE DEVICE REMOVE ...

Страница 17: ...ESS TERMINALS Solderless terminal dimensions Unit mm Round non insulated solderless terminal Round insulated solderless terminal Y non insulated solderless terminal Y insulated solderless terminal Terminal block shape Unit mm ...

Страница 18: ...3 Failure that could have been avoided if when our product was assembled into customer s device safeguards defined by legal regulations applicable to customer s device or functions or structures considered standard by the industry had been provided 4 Failure recognized as preventable if the consumed products specified in instruction manuals etc were normally maintained or replaced 5 Replacement of...

Страница 19: ...ortation atomic power electric power aerospace or medical applications please contact your nearest Mitsubishi sales representative Although this product was manufactured under conditions of strict quality control the product shall be systematically provided with backup and fail safe functions when it is used in facilities where breakdowns of the product are likely to cause a serious accident or da...

Отзывы: