29
Declining slope
[When the pipe is extended to left and taken out from the rear center]
Note (1) It is designed to collect moisture
accumulated on the rear face in the
drain pan. Be sure not to accommodate
the power cable, etc. above the chute.
¡
When arranging the pipe through a hole opened at the center, open the
knockout hole using nippers, etc.
(Drain pipe relocation procedure)
1.
Remove the drain pipe.
2.
Remove the drain cap.
3.
Insert the drain cap.
4.
Connect the drain pipe.
¡
Loosen the spring clamp and
securely insert the drain pipe.
Note: If it is inserted insufficiently,
water leakage could result.
Pipe accommodation space
¡
Loosen the spring clamp to
remove.
¡
Remove by hand or use
cutting pliers, etc.
¡
Securely insert the drain cap
removed in the step 2.
Note: If it is inserted insufficiently,
water leakage could result.
Chute
Wall
(4)
Installation of indoor unit
(a)
Hang the upper portion of the unit rear cover on the mounting board,
and then magnet on the lower unit portion will pull to fix the unit.
(b)
Be sure not to leave any trap on the drain pipe.
Wall
Slighty push
Mounting
block
1.5.3
Installation of outdoor unit
(1)
Installation of outdoor unit
(a)
Make sure that sufficient space for installation and service is secured.
(b)
Fix the leg sections of the unit on a firm base which will not play.
Attach cushion pads, etc. between the unit and the mounting fixtures not to transmit vibration to the building.
(c)
Attach a drain elbow, etc. under the drain port of the bottom plate to guide drain water. (Drain elbow should not be used
where days when temperature drops below 0˚C continue for several days. Draining may be disturbed by frozen water.)
(d)
When installing the unit at a higher place or where it could be toppled with strong winds, secure the unit firmly with founda-
tion bolts, wire, etc.
(2)
Connection of indoor and outdoor connecting wiring
(a)
Connect the wiring according to the number of the indoor terminal block. (Mis-wiring may cause the burning damage, and
make sure to connect correctly.)
Cooling only
Heat pump
type
type
1 BROWN
2 BLUE
3 BLACK
(40 : –)
4 GREEN
(40 : –)
Terminal block
YELLOW
GREEN
Terminal block
Earth terminal
Interconneting wire
Inverted slipe
Trap
(b)
When an abnormality is indicated on the outdoor unit for the cooling only model, check the fuse on the outdoor unit. If the
fuse is burnt out, replace it with new one.