– 16 –
Restarting has been blocked for 3 minutes after you have stopped,
to protect the unit.
The three-minute protection timer in the microcomputer automatically
starts up again. This function is not activated if you have disconnected
the power.
Please remember!
You cannot restart the unit immediately after you have stopped it.
(RUN light is on)
Not
operating?
Please wait for
three minutes.
The indoor fan may stop to prevent re-evaporation of dehumified
moisture and to save energy.
Some steam escapes during COOL operation
This may occur if the room's temperature and humidity are very
high. It disappears as soon as the temperature and humidity
decrease.
There is a slight smell
Air blown out during operation may smell. This is caused by
tobacco or cosmetics sticking to the unit.
You hear a slight gurgling sound
This is caused by refrigerating liquid moving within the unit.
You hear a slight cracking sound.
This is caused by heat expansion or contraction.
After a power cut or disconnection of the power plug, you
cannot re-start, even if power has been restored.
The memory circuit of the microcomputer has been wiped out. Use
the remote control to start the operation again
Air is not blown out when starting the DRY operation.
(RUN light is on)
Remote control signals are not received.
Moisture may form on the air outlet grilles.
If the unit is operated for a long time in high humidity, moisture
may form on the air outlet grilles and start dripping.
Remote control signals may not be received if the signal receiver
on the air conditioner is exposed to direct sunlight or other bright
light.
If so, cut out the sunlight or reduce the other light.
Air is not blown out when starting the HEATING operation.
RUN light blinks slowly
(1.5 sec ON, 0.5 sec OFF)
Air flow has stopped to prevent blowing out of cold air until the
indoor heat exchanger has warmed up (2 to 5 min.) (HOT KEEP)
Air is not blown out for 5 to 10 min. at HEATING operation.
RUN light blinks slowly
(1.5 sec ON, 0.5 sec OFF)
When outdoor temperature is low and humidity is high, the unit
sometimes performs defrosting automatically. Please wait. During
defrosting, water or steam may escape from the outdoor unit.
P.1-18/E