18
SRK-GZ
(3)
Flap control
Control the flap by AIRFLOW button on the wireless remote control.
(a)
Natural flow (AUTO)
The flap will be automatically set to the angle of air flow best to operation.
(i)
Starting time of operation
¡
The flap operation as shown above will be
repeated.
¡
When the room temperature controller (ther-
mostat) is activated, horizontal blowing is ap-
plied to prevent cool wind from blowing out.
Stops at the level position for
one minute.
s
In case of cooling
t
and dry operation
s
In case of heating
t
operation
Sway operation
Flap stops 3’50” on
this position.
Sway operation
(c)
Swing flap
Flap moves in upward and downward directions continuously.
Horizontal
blowing
(ii)
When not operating
The flap returns to the position of air flow directly below, when operation has stopped.
(b)
Memory flap (Excepted SRK 25 model)
While the flap is operating if the AIRFLOW button is pushed once, it stops swinging at an angle.
As this angle is memorized in the microcomputer, the flap will be automatically set to the angle when next operation is
started.
¡
Recommendable stopping angle of the flap
Slant forward
blowing
COOL•DRY
HEAT
Models
SRK25GZ-L1, 35GZ-L1
Model SRK502Z-L
Stops for approximately
13 seconds in this
position.
Thick line : Rapid movement
Thin line : Slow movement
Thick line : Rapid movement
Thin line : Slow movement
Stops for approximately
10 seconds in the
horizontal position.
s
During cooling and
t
dry operation
s
During heating
t
operation