![Miteq RL1-095145 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/miteq/rl1-095145/rl1-095145_manual_1807872036.webp)
Operation | 30
A3 NORMAL
35
34
33
A3 FAULT
33
34
35
A4 NORMAL
16
17
37
A4 FAULT
37
17
16
SIGNAL/FRAME GROUND
4
1:2 Status Output Connector, Contact Closure Option Only (J2) -
Pin designations are indicated in Figure 3-4.
TABLE 3-4. 1:2 STATUS OUTPUTS (CONTACT CLOSURE) (J2)
DESCRIPTION (COMMANDS)
CLOSED
COMMON
OPEN
A1 & A2 ONLINE, A3 STANDBY
1
4
2,3
A2 & A3 ONLINE, A1 STANDBY
2
4
1,3
A1 & A3 ONLINE, A2 STANDBY
3
4
1,2
AUTO
5
6
7
MANUAL
7
6
5
DESCRIPTION (STATUS)
A1 & A2 ONLINE, A3 STANDBY
8
11
9,10
A2 & A3 ONLINE, A1 STANDBY
9
11
8,10
A1 & A3 ONLINE, A2 STANDBY
10
11
8,9
LOCAL
26
27
28
REMOTE
28
27
26
AUTO
29
30
31
MANUAL
31
30
29
SYSTEM NORMAL
25
24
23
SYSTEM FAULT
23
24
25
A1 NORMAL
14
13
12
A1 FAULT
12
13
14
A2 NORMAL
17
16
15
A2 FAULT
15
16
17
A3 NORMAL
22
21
20
A3 FAULT
20
21
22
SIGNAL/FRAME GROUND
36
Remote Interface Connector (J2) -
pin designations are indicated in Table 3-5.
TABLE 3-5. REMOTE INTERFACE CONNECTOR (J2)
RS232
PIN
DESIGNATION
1
GROUND
2
Tx DATA
3
Rx DATA
7
GROUND
RS485 & RS422 (J2 & J3)
1
GROUND
3
DATA OUT -
5
DATA IN -
7
DATA OUT +
9
DATA IN +