Operation | 21
COMMAND AND ERROR CODE SUMMARY
LEGACY COMMAND SET
ASCII Character String
Function
P
On-line/Standby Status
Q
Alarm Status
R
Mode
S
On-line/Standby Status
U
Mode
REMOTE COMMAND SET
ASCII Character String
Function
ALR
Alarm Status Combined
ATT
Attenuation
CLK
Real Time Clock
LIM
Amplifier Current Limits
LOG
Log Entries
MOD
Mode (cmd same as U, query same as R)
PRI
Amplifier Priority (1:2 unit only)
SLP
Slope
SWT
On-line/Standby Status (cmd same as P, query same as S)
VLT
Voltage and Current Readings
ERROR CODES
ASCII Character
Function
a
Command not recognized
b
Illegal parameter or parameter out of range
c
Unit in Local mode
d
Busy
SYSTEM FAULT STATUS = ALR
There is no SET command.
The QUERY command requires no parameters.
Command
Parameters
Remote Command Sequence: ?ALR
Unit Response:
?ALRabc
?ALR: Status indicator
a-c: “0” or “1: ASCII numeric character
0 = No fault
1 = Fault
a = 1 = Any Amplifier Alarm
b = 2 = Any Switch Alarm
c = 3 = Any Power Supply Alarm