TA7104 /7108 Hardware Installation
155/1531-ANF 90114 C 2017-03-08
8
Do not work alone if potentially hazardous conditions exist.
Never assume that power is disconnected from a circuit. Always check.
Do not perform any action that creates a potential hazard to people or makes equipment unsafe
Warning:
This equipment must be installed and maintained by service personnel. Incorrectly
connecting this equipment to a general-purpose outlet could be hazardous. The telecommunications
lines must be disconnected before unplugging the main power connector.
Preventing Electrostatic Discharge Damage
Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to
earth ground to channel unwanted ESD voltages to ground safely.
3.3
REQUIRED MOUNTING TOOLS AND EQUIPMENT
You will need the following tools and parts to properly install the TA7104/7108:
ESD-preventive wrist strap.
In addition, you might need the following external equipment:
Modem for remote access.
RJ-45 cables for the WAN and LAN connections.
3.4
UNPACKING AND INSPECTION
If you ha
ven’t already done so, unpack the TA710x device. Carefully remove it from the package and
packing material. The TA710x package contains the following items:
1 x TA710x unit
1 x power supply for the country in which you are using the TA710x
1 x BumponTM kit for desktop use
1 x Printed Flyer
You may also need additional 10/100 BaseT Ethernet RJ-45 cables.
3.5
LOCATION AND MOUNTING REQUIREMENTS
Warning:
The analog lines of the TA7104/7108 are not intended for connection to a
telecommunication network that uses outside cable.
Warning:
To prevent fire or shock hazard do not expose the unit to rain or moisture.
The TA7104/7108 is suited for use in an office or residential environment where it can be wall-
mounted or free standing.
Location
Install the TA7104/7108 in a well-ventilated location where it will not be exposed to high temperature
or humidity. Do not install the TA7104/7108 in a location exposed to direct sunlight or near stoves or
radiators. Excessive heat could damage the internal components.
When deciding where to position the TA7104/7108, ensure that:
The TA7104/7108 is accessible for future upgrade, maintenance and troubleshooting, and cables
can be easily connected.
The cabling is away from the following:
Sources of electrical noise such as radios, transmitters, and broadband amplifiers.
Power lines and fluorescent lighting fixtures.
Water or moisture that could enter the casing of the TA7104/7108.