Содержание MV800C

Страница 1: ...MITECH CO LTD www mitech ndt com www ponpe com ...

Страница 2: ... 2 Structure and Outline 3 2 1 Main Unit 3 2 2 Display 3 3 Keypad Definition 3 4 Operation 3 4 1 Preparations Before Using 3 4 2 Selection of Probe 4 4 3 Frequency Switch 4 4 4 Set Vibration Parameters 4 4 5 Set Frequency Range 5 4 6 Signal Output 5 4 7 Troubleshooting 5 5 Cautions 5 6 The Standard of Vibration Intensity 5 7 Maintenance Notes 6 User Notes 7 sale ponpe com ...

Страница 3: ...ccordance with national standard the measurement value can be compared with ISO2372 to judge the running state of device Signal output equips with earphone can realize the function of stethoscope Signal output equips with oscillometer to monitor and record the vibration 1 3 Technical Parameters Vibration pickup Integrated ring acceleration transducer Measurement range displacement 0 001 1 999mm Pe...

Страница 4: ...do the new test 4 Release the measurement key for about 1 minute it will auto power off 4 Operation 4 1 Preparations Before Using 1 Install battery Open the cover put in the battery 1 Check the battery voltage Configuration NO Part name QTY Remarks Standard config 1 Main unit 1 2 Short probe 1 3 6F22 battery 1 4 User s manual 1 5 Warranty 1 Optional config 6 Long probe 1 7 Earphone 1 8 Sheathe 1 9...

Страница 5: ...there is a flat frequency above 1KHz there is no need to use probe Short probe Short probe is necessary for frequency of 10Hz 10KHz It is more reliable Long probe When the short probe is hard to test use 8cm long probe In low frequency of 10 1KHz long probe has good response above 1KHz the response will reduce No probe It is ok when the surface is well connected if the sensor and workpiece is not ...

Страница 6: ...means the vibration is caused be high frequency such as the deterioration of rolling bearing gear tooth broken etc 5 Cautions When using integrated vibration meter the strength on probe should between 5N 10N Pay attention to the right angle of probe When using different probes the results might be different especially in high frequency Do not use pincers to avoid damage Theoretically MV800C can te...

Страница 7: ...is almost out please change the battery Take out the battery when not using to avoid the battery leakage After using clean the tester with soft cloth avoid rain or oil infiltration When there happens abnormal things please do not self dismantle the tester deliver it to our company sale ponpe com ponpe com ...

Страница 8: ...eporting to repair sheet In accordance with the international relevant regulations the following are not within the scope of free warranty Damage caused by man made or improper keeping Self dismantle or non special repair shop dismantle Do not follow the requirement of service registration or warranty expired Consumable parts Service promise MITECH users have lifelong maintenance service Free main...