background image

GARDEN-TOWER IR

 

Installation and user manual  

Page 15 of 24 

Alignment 

1. 
 
2. 
 
 
 
 
 
 
 
 
 
 
 
 
 
3. 

Barrier power supply (see page 10) 
 
Check that all the red leds (ALM LEDs) on the 
expansion and tamper boards of the RX optics 
are all off (Image 1) 
 
 
 
 
 
 
 
 
 
 
 
If one or more leds are not off, gently adjust the 
relevant lenses in a horizontal and vertical 
direction towards the transmitters until all the 
leds are turned off. 
If one or more leds are not turned off, go directly 
to the instrumental alignment procedure 
described on page 16.  
    

 

NORMAL 

NOISE 

TEST 

LED ALM 

T.P. 

MI-TECH.                        

RX

                       FEBRX  

Image 1 

WARNINGS: 
Before the instrumental alignment verify the following on the receiver motherboard:   

the blinding led must be switched off 

the AND and S.LOW jumpers must be set to OFF 

the MASK and SPEED trimmer regulation must remain in vertical position

 

Image 2 

VERTICAL 

ADJUSTMENT  

BY 30° 

HORIZONTAL 

 ADJUSTMENT BY 180° 

Содержание GAR102-RX

Страница 1: ...GARDEN TOWER IR IR COLUMNS Available in terminal and bi directional versions Installation and user manual MADE IN ITALY ...

Страница 2: ...d mounting GAR GR base 7 Receiver and transmitter motherboards Page 12 Power supply Page 14 Alignment Page 15 16 17 Settings and programming Page 18 Description of signalling leds 18 Jumpers and trimmers description 19 Fixing the column Page 8 Tamper height adjustment inserting the tube and closing the column Page 9 Technical specifications and consumption Page 20 Additional components Page 5 Note...

Страница 3: ...onization GARDEN and TOWER IR are more suitable for harsher environments and weather situations low temperatures fog humidity wind gusts thanks to the built in automatic temperature control device the disqualification system and sturdy aluminum structure WARNINGS Use shielded cables Observe the minimum distances between the TX and RX columns see table on page 20 In areas subject to intense fog for...

Страница 4: ...bracket GAR WL Boards optical groups and heating system Terminal version RX or TX Motherboard 1 RX or TX Expansion boards From 1 to 4 RX or TX Tamper boards 1 RX or TX Optical groups From 2 to 5 RX or TX Heating resistors From 2 to 5 Bi directional version Motherboard 1 couple 1 RX 1 TX Expansion boards From 1 to 4 couples max 4 RX 4 TX Tamper boards 1 couple 1 RX 1 TX Optical groups From 2 to 5 c...

Страница 5: ...ket for wall mounting 200 x 210 mm GARPOW Dual power supply 1 for column if required it is installed up GAR LAMP CO or WH Globe light fixture with lamp holder E27 Diameter 32 cm Available colours white WH and cognac CO LUMYA Embedded light fixture white colour with lamp holder Height 25 cm E27 GAR PRCAP Anti climbing pressure cap TW CAMCAP Universal camera support ...

Страница 6: ...at could interfere with the beams Verify that the optics of the transmitter and receiver units are not exposed to direct sunlight at dawn and sunset Do not use switching power supplies that might cause electrical disturbances Mounting options Columns may be mounted in two ways with a specific wall mounting bracket code GAR WL with a specific ground mounting base code GAR GR Wall mounting GAR WL br...

Страница 7: ...a cement base in which to anchor the clamps provided It is necessary to use a corrugated pipe Ø 20 mm for passage of cables FIXING WITH GUSSETS Drill 3 holes of Ø 8 mm in the ground level with the base fixing holes Insert M8 steel gussets not supplied and fix the base 20 cm 20 cm 20 cm FRONT VIEW SIDE VIEW 20 cm TOP VIEW Cables insertion hole Ø 32 ...

Страница 8: ...Insert the lower cap into the base guide Insert the aluminium bar into the base guide and into the relevant slot in the lower cap Insert the connecting bracket between the lower cap and the aluminum bar Screw 2 M6x20 screws through the bracket and the base and 2 M6x25 screws through the bracket and the bar ...

Страница 9: ... adjustment Adjust the tamper height using the two jagged edge washers A and B see image Closing the column Position the top cover and screw it to the column using the supplied screws provided with o ring Inserting the tube Insert the polycarbonate tube from above making it slide down into the slot and inserting it into the lower cap A B ...

Страница 10: ...IMETER PROTECTION With terminal columns 3 SIDES PERIMETER PROTECTION With terminal and bi directional columns WARNING ENSURE THAT THE COLUMNS ARE INSTALLED IN A STRAIGHT ROW For a correct positioning of the columns refer to the following diagram contact the supplier for more information TX RX TX RX TX RX YES TX RX TX RX TX RX NO TX RX RX TX TX RX YES ...

Страница 11: ...mns come with crossed beams to ensure maximum protection For visibility purposes the beams in this drawing are linear WARNING Ensure no interference is caused by the presence of photocells for automatic gates or infrared cameras as these may blind the barriers COLUMNS IR BEAMS TRANSMISSION ...

Страница 12: ...SOR BEAMS SELECTOR Barrier with 2 lenses no jumper Barrier with 3 lenses jumper 3 inserted Barrier with 4 lenses jumper 3 and 4 inserted Barrier with 5 lenses jumper 3 4 and 5 inserted HEATING POWER SUPPLY 24 Vac LED1 S LOW LOW SIGNAL LED2 MASK MASKING LED3 DETECT DETECTION LED4 ALM ALARM LED5 HTR HEATING LED6 POWER POWER SUPPLY AUTOMATIC FOG DISABLING ON ACTIVE OFF NOT ACTIVE ON OFF LEDS AND FUNC...

Страница 13: ...STOR THERMAL SENSOR BEAMS SELECTOR Barrier with 2 lenses only jumper 2 inserted Barrier with 3 lenses only jumper 3 inserted Barrier with 4 lenses only jumper 4 inserted Barrier with 5 lenses only jumper 5 inserted HEATING POWER SUPPLY 24 Vac LED2 TEST MODE LED3 HTR HEATING LED4 POWER SUPPLY ON OFF LEDS POWER SUPPLY 12 V 0 V GND TAMPER OUTPUT LED1 CLOCK FLASHING LED 2 3 4 5 6 7 8 9 10 BEAM ON OFF ...

Страница 14: ... Example of power supply connection with GAR POW unit With a power supply it is possible to feed a pair of barriers RX TX or RX RX or TX TX WARNINGS Always use filtered and stabilized 230 Vac voltage Then check the cabling before connecting the power supply RX MOTHERBOARDS ...

Страница 15: ...ds the transmitters until all the leds are turned off If one or more leds are not turned off go directly to the instrumental alignment procedure described on page 16 NORMAL NOISE TEST LED ALM T P MI TECH RX FEBRX Image 1 WARNINGS Before the instrumental alignment verify the following on the receiver motherboard the blinding led must be switched off the AND and S LOW jumpers must be set to OFF the ...

Страница 16: ...e the TEST jumper on the first TX expansion board to ON MULTIMETER Measurement in Vcc Reference value approx 4V Cable supplied red black Led TX Jumper insertion Flat cable NOTES a some multimeters might display a voltage that is up to 50 lower than the real value therefore check the tester is working correctly b the use of some transceivers to communicate during installation could affect the multi...

Страница 17: ... at the bottom and repeat from step 3 the alignment of all the remaining TX expansion boards MULTIMETER Cable supplied red black Measurement in Vcc Reference value approx 4V 6 Ensure all the TEST jumpers of the TX motherboard and of the TX expansion boards are set to OFF FINAL TEST Double lens version verify that the barrier triggers an alarm signal when both lenses of each optical group are cover...

Страница 18: ... an electromagnetic interference or a wiring problem that may affect the correct functioning of the barrier Led DETECT Irregular transmission signal This led is generally OFF in ordinary operating conditions The led blinks if one or more transmitter signals are not detected by the receivers It lights permanently if all the transmitters signals are not detected by the receivers Verify alignment and...

Страница 19: ...ables the signal LEDS Trimmer SPEED For adjusting the tripping time from 50 ms to 500 ms the delay increases by turning the trimmer clockwise Trimmer MASK For adjusting the sensitivity of the blinding function the sensitivy increases by turning the trimmer clockwise RX motherboard Jumper BEAM Number of beams selector see diagram on page 13 Jumper TEST To use for alignment see page 16 Jumper LEDS I...

Страница 20: ...er output Contact NC NA Led indicators Power supply anti masking heating low signal alarm detection IR signal Pulsed coded Standard compliance EN 50131 1 and CEI 79 3 ROhs compliance 2011 65 UE Protection class IP 65 Warranty 3 years COLUMN TX RX TOTAL CONSUMPTION TW102D GAR102D 120 mA 110 mA 230 mA TW102 RX GAR102 RX 110 mA 110 mA TW102 TX GAR102 TX 120 mA 120 mA TW153D GAR153D 120 mA 150 mA 270 ...

Страница 21: ...GARDEN TOWER IR Installation and user manual Page 21 of 24 Notes ...

Страница 22: ...GARDEN TOWER IR Installation and user manual Page 22 of 24 ...

Страница 23: ...GARDEN TOWER IR Installation and user manual Page 23 of 24 ...

Страница 24: ...n Via Ramazzone 23 43010 Fontevivo PR Italy Phone 39 02 48006383 Fax 39 02 48025620 tech mitech security com www mitech security com MADE IN ITALY GARDEN TOWER IR Rev 18 03 2019 MITECH srl reserves the right to change the information in this document without warning ...

Отзывы: