MistAway® Drum-Based Misting Unit 

Gen 1.3

Operations Manual

MistAway’s Drum

-Based Misting Unit, Gen 1.3, is designed to 

atomize a dilute botanical insecticide (typically contained in a 55 
gallon drum) through an installed nozzle circuit to control 
mosquitoes and other annoying insects.

The capacity of the unit is dependent on the configuration of the 
nozzle circuit.  A practical field maximum for one zone is about  
90 nozzles (not all in series) connected by 900 feet of tubing.

The unit may be programmed to mist up to 24 times daily, with 
each mist cycle having its own independent duration.  A typical 
program will consist of 2 to 3 mist cycles per day, each with a 45 

60 second duration, for a daily total of 90 

180 seconds.

The unit will also mist in response to a signal from a handheld 
remote transmitter for a duration programmed by the user.

Base Functionality

Optional Equipment and Functionality

MistAway® Drum-Based Misting Unit 

Gen 1.3

Operations Manual

Agitating Valve

:  Each mist (including remote mists) will be 

preceded by an agitation cycle that will ensure thorough mixing 
of the drum contents prior to misting.  In addition, there is a 
capability to program a once-daily agitation that is independent 
of any programmed or remote mist.  The agitating valve also 
eliminates the possibility of a siphon emptying the drum 
contents.

Leak Detection:  

In the event of a leak in the misting nozzle 

circuit, this option will shut-off the unit until the leak can be 
repaired.

Electronic Anti-Siphon Valve

:  For units without agitation, 

addition of this valve eliminates the possibility of a siphon.

Wind Sensor

: Sensor input will inhibit a programmed mist if the 

wind speed is higher than a user-defined limit for a 5 minute
period following the scheduled mist.

Zone Kit

:  Kit will enable the unit to either independently 

manage areas with two different application schedules or 
effectively double the protected area that the unit would 
otherwise support.

iMistAway Module: 

Allows the unit to be remotely monitored 

and controlled via an Internet connection.

Содержание Gen 1.3

Страница 1: ...MistAway Drum Based Misting Unit Gen 1 3 Operations Manual Copyright 2020 by MistAway Systems Inc...

Страница 2: ...The unit will also mist in response to a signal from a handheld remote transmitter for a duration programmed by the user Base Functionality Optional Equipment and Functionality MistAway Drum Based Mi...

Страница 3: ...tion statement should be securely attached to the unit reservoir in a weatherproof pouch Strictly follow label instructions regarding storage and disposal of insecticide and container Nozzle Circuit I...

Страница 4: ...or empowered to give any other warranty or to assume any other liability on behalf of MSI Warranty Conditions This warranty is extended only to the original Purchaser and is not transferable A purchas...

Страница 5: ...button while plugging the unit back in Mist Cycles remote duration and number of nozzles must be reentered Section 3 Using the Controller Section 4 Using the Remote Note The handheld remote transmitt...

Страница 6: ...e kit using instructions with the kit Plug unit into outlet and confirm controller boots up Fill drum through bung on lid and set level 12 15 inches of water only DO NOT ADD CONCENTRATE YET If 125 gal...

Страница 7: ...o label or link for dosing instructions Use Dosing and Days to Empty Calculator mistaway com Use funnel to add concentrate to drum through bung on lid Apply adhesive backed label supplied with concent...

Страница 8: ...approved insecticides and mixing guidance Conventional Insecticide Formulations Exempt or Green Insecticide Formulations Section 6 Managing the Insecticide It is important to note that there are diff...

Страница 9: ...to maintain an air gap of 6 between the tip of the hose and the fluid in the drum o Measure concentrate and use a funnel to add it through the bung o Continue filling the drum with water to the desir...

Страница 10: ...pressure gauge and from inlet left side of flow meter and tilt drum to left allowing water to drain Reconnect tubing Replace controller in well 4 Clear water from nozzle circuit filter if equipped 5 U...

Страница 11: ...Intake Line and Filter Pump intake positioned near bottom of drum Filter ensures debris is not drawn into pump and nozzle circuit J tube Mixing Assembly on units with optional Agitating Valve To ensur...

Страница 12: ...in circuit in milliliters per minute Used in tank level indicator Empty shut off and leak detection calculations Default is 40 mL min TOL Error tolerance for nozzle circuit flow rate Controls sensiti...

Страница 13: ...n at end of mist cycle to allow pressure in nozzle circuit to decay and close nozzles quickly INS Unit is in Inspection Mode and will mist for 20 minutes or until stopped MST Unit is misting NOZ00 Uni...

Отзывы: