GUIDE TO INSTALLATION AND OPERATION
20
| RCP-100
RCP100.xxx> makeupdatedisk
RAM disk initialized - size is 5000 blocks...
Volume name is 3.0.0
Current directory set to 3.0/
RCP100.xxx>
Do not close the Telnet application.
Note: If the command
makeupdatedisk
is not recognized by RCP-100, type the following command,
which gives the same result:
makeramdisk 5000
5.
Start the WS_FTP application
6.
Connect to RCP-100 using the following parameters:
•
Host Name/Address:
(RCP-100 IP address)
•
Host type:
Automatic detect
•
User
ID:
Anonymous
•
Password:
guest
WARNING
: Select the “
BINARY
” file transfer mode for steps 7 and 13!
Using another transfer mode could lead to an incorrect data transfer, and the RCP-100 will
no longer be able to work, or to be reprogrammed via Telnet. It will require factory
reprogramming.
7.
In WS-FTP, copy the file rcp_update.bin located in the same directory , (left window of WS_FTP) to
RCP-100 (right window of WS_FTP). Use the Binary file transfer mode - see WARNING!
8.
Disconnect WS_FTP from RCP-100 (click " Close " button)
9.
Return to the Telnet application window and type:
updatercp
. On the telnet application window the
written flash sectors will be displayed gradually.
10.
After the file is copied in the RCP-100 flash memory, type
restart
. RCR-100 will restart with the new
firmware.
In the following steps the * typ files will be loaded into the RCP-100 flash memory.
11.
Restart the Telnet application telnet connect to RCP-100 with the IP address of RCP-100. Type
makeramdisk
. The following message will be displayed:
RCP100.xxx> makeramdisk
RAM disk initialized - size is 2048 blocks...
Volume name is 3.0.0
Current directory set to 3.0/
RCP100.xxx>
12.
In the Telnet window, type
cp -r 45.0 3.0
13.
In WS-FTP, copy all the files * typ of the new version, located in the same directory, (left window of
WS_FTP) to RCP-100 (right window of WS_FTP). Use the Binary file transfer mode - see WARNING!
14.
Disconnect WS_FTP from RCP-100 (click the " Close " button)
15.
In the Telnet application window, type
copytoflash
. The following message will be displayed: