GUIDE TO INSTALLATION AND OPERATION
FXE-1501 |
11
This window allows a more comprehensive management of alarms than the menu.
Status / Name
This column lists, beginning at the top, all the individual alarms that are available on this card.
Each has a status icon at the left that will be either green (no alarm) or red (the error
condition has been detected and the alarm is ON).
At the bottom are some composite alarms
(Card LED
and
Overall
) whose status is
programmed by user selections made in the similarly-named columns
Card LED
This column contains user-configurable settings that allow the user to determine the
contribution of each of the individual alarms to the Card LED composite alarm. This alarm
determines the color displayed on the Status LED visible on the front edge of the card.
See below for a description of how to use these settings.
Overall Alarm
This column contains user-configurable settings that allow the user to determine the
contribution of each of the individual alarms to the Overall composite alarm. This alarm
determines the color of the status icon at the top left of the iControl panel for this card at the
user’s workstation, and the status icon displayed for this card in other iControl applications
such as iControl Navigator.
See below for a description of how to use these settings.
GSM Contribution
This column contains user-configurable settings that allow the user to determine the
contribution of each of the individual alarms to the GSM alarm status for the card. The GSM
(General Status Manager) is a dynamic register of all iControl system alarms, and is also an
alarm provider for external applications. The possible values for this contribution are related
to the Overall alarm contribution:
•
If the Overall alarm contribution is selected as Disabled, the GSM alarm contribution
can be set to any available value
•
If the Overall alarm contribution is selected as any level other than disabled, the GSM
contribution is forced to follow the Overall Alarm.