26
3.9.3 Horizontal Blanking Setting
For the composite analog output, the blanking interval can be set to
narrow
(as
per SMPTE 259M : all pixels are passed) or
wide
(as per SMPTE-170M).
To select the desired horizontal blanking setting, perform the following steps:
1. Press SELECT to enter the menu.
PROC
is displayed.
2. Press the “+“ push-button until
COMP
is displayed.
3. Press
SELECT;
SETP
is displayed. Press the “+“ push-button until
HBLK
is
displayed.
4. Press SELECT to enable the Horizontal Blanking menu. The current
horizontal blanking selection
is displayed.
5. Use the “+” or “–“ push-button to choose the desired horizontal blanking
selection. Press “+“ and “–“ push-buttons simultaneously to select
WIDE
(default setting).
6. Press SELECT to store the new horizontal blanking selection.
HBLK
is
displayed.
7. Press ESC to return to
COMP
.
8. To return to normal mode, press ESC.
3.9.4 Closed Captioning
This control allows the set-up on line 21 to be turned off when closed captioning is
present. To select between ON and OFF states, perform the following steps:
1. Press SELECT to enter the menu.
PROC
is displayed.
2. Press the “+“ push-button until
COMP
is displayed.
3. Press
SELECT;
SETP
is displayed. Press the “+“ push-button until
CC
is
displayed.
4. Press SELECT to enable the Closed Captioning menu. The current status of
set-up on line 21 is displayed.
5. Use the “+” or “–“ push-button to choose the desired line 21 set-up status.
Press the “+ “ and “–“ push-buttons simultaneously to set the line 21 setup to
OFF
(default setting).
6. Press SELECT to store the new line 21 set-up selection.
CC
is displayed.
7. Press ESC to return to
COMP
.
8. To return to normal mode, press ESC
3.10 Configuration
Up to 5 different configurations – referred to as User Presets - may be stored into
the on-board non-volatile memory. Each of these configurations includes the
stored settings for all of the parameters, for 525-line
AND
625-line formats. This
menu also enables automatic calibration of the Y, Cb and Cr gains and black
level.
3.10.1 Loading User Presets
To load a User Preset, follow these steps:
1. Press SELECT to enter the menu.
PROC
is displayed.
2. Press the “ + “ push-button until
CONF
is displayed.
3. Press
SELECT;
LOAD
is displayed.
Содержание DVP-101i
Страница 36: ...31 5 Schematic DIagrams ...