GUIDE TO INSTALLATION AND OPERATION
LGK-3901/DSK-3901 |
53
6.3 Local Control using the Densité Frame Control Panel
6.3.1 Overview
Push the SELECT button on the LGK-3901/DSK-3901 card edge
(see section 4) to assign the local control panel to operate the
LGK-3901/DSK-3901. Use the control panel buttons to navigate
through the menu, as described below.
All of the cards installed in a Densité frame are connected to the
frame’s controller card, which handles all interaction between the
cards and the outside world. There are no operating controls
located on the cards themselves. The controller supports remote
operation via its Ethernet ports, and local operation using its
integrated control panel.
The local control panel is fastened to the controller card by a
hinged connector, and when installed is located in the front
center of the frame, positioned in front of the power supplies. The panel consists of a display unit capable of
displaying two lines of text, each 16 characters in length, and five pushbuttons.
The panel is assigned to operate any card in the frame by pushing the SELECT button on the front edge of that card.
•
Pushing the CONTROLLER button on the control panel selects the Controller card itself.
•
The STATUS LED on the selected card flashes yellow.
The local control panel displays a menu that can be navigated using the four pushbuttons located beneath the display.
The functionality of the push buttons is as follows:
[+] [–]
Used for menu navigation and value modification
[SELECT] Gives access to the next menu level. When a parameter value is shown, pushing this button once
enables modification of the value using the [+] and [–] buttons; a second push confirms the new value
[ESC]
Cancels the effect of parameter value changes that have not been confirmed; pushing [ESC] causes the
parameter to revert to its former value.
Pushing [ESC] moves the user back up to the previous menu level. At the main menu, [ESC] does
not
exit the menu system. To exit, re-push the [SELECT] button for the card being controlled.
If no controls are operated for 30 seconds, the controller reverts to its normal standby status, and the selected card’s
STATUS LED reverts to its normal operating mode.
6.3.2 Menu for local control
The LGK-3901/DSK-3901 has operating parameters that may be adjusted locally at the controller card interface.
•
Press the SELECT button on the LGK-3901/DSK-3901 front card edge to assign the Densité frame’s local
control panel to the LGK-3901/DSK-3901
•
Use the keys on the local control panel to step through the displayed menu to configure and adjust the LGK-
3901/DSK-3901.
Note:
The complete menu structure is shown in Annex 1 to this document, beginning on page 96.
SELECT
ESC
+
-
CONTROLLER
Figure 6.1
Densité Frame local control panel
USO