Metadata
The
Metadata
tab offers setting options for the output LTC
signal for the embedded time code, RS-422 signal, GP1
and GP2.
The
LTC Output
window allows the user to select the
source of the time code appearing at the LTC output (ATC,
DVITC). For an HD-SDI input, using the
HD ATC Select
drop down menu, select the ATC signal to be disembedded
(first ATC or second ATC).
For an SD-SDI input, using the
SD DVITC line
drop down
menu, select the desired line to be disembedded. If the
input DVITC is in a 525 format, the available selections will
be auto or lines number 10 to 20. If the input DVITC is in
625 format, the Auto option remains, but the line numbers
vary from 7 to 22.
The delay drop down menu allows the user to add delay to
the extracted time code while translated to LTC. The delay
is selectable from none to 3 frames.
The
Status
tab shows the detection of input embedded
time code, RS-422, GPI 1 and GPI 2 signals. When
present, the status icons turn to green.
Monitoring Output
The
Monitoring Output
tab is only available on the ADX-
1852. It allows the conversion of AES digital audio to
stereo analog audio signals.
Using the
Audio Select
drop down menu, select the AES
output source for the stereo analog audio conversion.
The
OdBFS Level
drop down menu allows the user to
adjust the output level in 1 dB steps for an output level
range of +12 dBU to +24 dBU at full scale amplitude.
The
VBit
drop down menu allows the user to block
monitoring of invalid AES outputs according to the validity
(V) Bit status. The V-Bit can have two values:
‘0’, AES output is valid and can be converted into an
analog audio signal.‘1’, AES output is invalid and
cannot be converted into an analog audio signal.
By selecting
mute
in the
VBit
drop down menu, the AES
outputs flagged as invalid by the V-Bit will not be
converted, while the data flagged as valid will pass through
and be converted. By selecting
pass
, the user ignores the
V-Bit status and forces the conversion.
Test
The
Test
menu allows the user to enable test signals on
the AES and LTC outputs for troubleshooting purposes.
Factory
Clicking the
Load Factory
button will restore all of the
adjustable parameters to a factory-preset state. Those
preset settings are indicated by an underline in the
ADX-
1842 and ADX-1852 menus
on pages 4 and 5 of this
manual.
Enables a test tone (1 KHz, R-steady,
L-pulsed, at-18 dBFS) in each of the
four AES outputs individually
Enables an output LTC test loop (10
second loop starting at 23:59:00:00)