![Mirage IVEH121A Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/mirage/iveh121a/iveh121a_owners-manual_1805332060.webp)
60
Test Run
BEFORE TEST RUN
TEST RUN INSTRUCTIONS
Only perform test run after you have
completed the following steps:
• Electrical Safety Checks - Confirm
that the unit’s electrical system is safe
and operating properly.
• Gas Leak Checks - Check all fare nut
connections and confirm that the sys-
tem is not leaking.
• Confirm that gas and liquid (high and
low pressure) valves are fully open.
You should perform the Test Run for at
least 30 minutes.
1
. Connect power to the unit.
2.
Press the ON/OFF button on the re-
mote controller to turn it on.
3.
Press the MODE button to scroll
through the following functions, one at a
time:
• COOL - Select lowest possible
temperature
• HEAT - Select highest possible
temperature
4.
Let each function run for 5 minutes, and
perform the following checks:
Содержание IVEH121A