54
DO NOT DEFORM PIPE WHILE
CUTTING
Be extra careful not to damage, dent, or
deform the pipe while cutting. This will
drastically reduce the heating efficiency of
the unit.
Step 2: Remove burrs
Burrs can affect the air-tight seal of refrigerant
piping connection. They must be completely
removed.
1.
Hold the pipe at a downward angle to prevent
burrs from falling into the pipe.
2.
Using a reamer or deburring tool, remove all
burrs from the cut section of the pipe.
4.
Remove PVC tape from ends of pipe
when ready to perform flaring work.
5.
Clamp flare form on the end of the pipe.
The end of the pipe must extend beyond
the edge of the flare form in accordance
with the dimensions shown in the table
below.
Step 3: Flare pipe ends
Proper flaring is essential to achieve an airtight
seal.
1.
After removing burrs from cut pipe, seal the
ends with PVC tape to prevent foreign materials
from entering the pipe.
2.
Sheath the pipe with insulating material.
3.
Place flare nuts on both ends of pipe. Make
sure they facing in the right direction, because
you can’t put them on or change their direction
after flaring. See Fig. 5.3.
PIPING EXTENSION BEYOND FLARE FORM
Содержание IVEH121A
Страница 6: ...6 Unit Specifications and Features Unit Parts...
Страница 16: ...16 Troubleshooting When troubles occur please check the following points before contacting a repair company...
Страница 31: ...31 INSTALLATION...
Страница 35: ...35 Owner s Installation manual...
Страница 36: ...36 Installation Summary Indoor Unit...
Страница 37: ...37...
Страница 62: ...6700 Gateway Park Dr Unit 6 San Diego CA 92154 Ph 619 426 0033 mirageappliances us...