..................................................AUTOMATIC WATER SOFTENER

 

 

MW-40

 DEMAND TIMER FEATURES, SETTINGS, AND SERVICE, continued 

 
feature / service: AUTOMATIC MW-40 DIAGNOSTICS ................................................................  

The timer computer has a self-diagnostic function for the 
electrical system (except input power and water meter). 
The  computer  monitors  the  electronic  components  and 
circuits for correct operation. If a malfunction occurs, an 
error code appears in the timer display. 

The  following  chart  shows  the  error  codes  that  could 
appear,  and 

possible

  defects  for  each  code.  While  an 

error  code  is  displayed,  the  RECHARGE  and  DATA 
buttons remain operable so you can perform the Manual 
Initiated Electronics Diagnostic. 

 
 
 

ERROR CODE DISPLAYED 

 

Err 01 

Err 03 

Err 04 

Err 05 

POSSIBLE DEFECT 

!

  motor  inoperative   

!

  wiring  harness,  or  connection  to  switch   

!

  position 

switch  

!

 valve defect causing high torque 

!

 timer (PWA) 

TO REMOVE AN ERROR CODE

: (1) unplug transformer (2) correct defect (3) plug transformer in (4) Wait for at least 12 minutes. 

The error code will return if the reason for the error code was not corrected. 

 

feature / service: ELECTRONIC SYSTEM PROFILE ....................................................................  

The  Miracle  Water  demand  timer  ESP  feature  provides  the  homeowner  or  servicer  with  the  latest  in  softener 
performance and electronic diagnostic technology. ESP is the transmission of electronic data  from the softener timer, 
through a telephone, to a remote personal computer equipped to receive the data. The personal computer decodes 
the  data  and  provides  a  detailed  report  of  the  softener’s  up  to  date  performance.  Some  of  the  information  ESP 
provides includes: 

"

  average  daily  gallons  of 

soft

  water  used  by  the 

household 

"

 average time between recharges 

"

 days since the last recharge 

"

 total number of recharges since start-up 

"

  if  an  electrical  power  outage  occurred,  and  how 

long it lasted 

"

  current  status  of  the  following  electrical 

components, and if a problem was found in a circuit 

!

 computer board   

!

 wire harness 

!

 valve motor   

!

 switch (valve positioning) 

!

 softener water meter 

         

 
This  report  is  immediately  available  to  trained  technicians.  With  this,  they  are  able  to  determine  if  an  electrical 
problem exists, based on factual, current information, and to offer expert advise if needed. A printout of this report is 
also available for a nominal charge. Ask about it when you call the toll free number shown on the next page. 
 

21

Содержание MW-40

Страница 1: ...0 12 3 03456 3 7 8...

Страница 2: ...r replace any part which we find defective because of faulty materials and workmanship or corrosion You pay only freight to our factory and local labor charges ONE YEAR ON COMPLETE UNIT THREE YEARS ON...

Страница 3: ...G INSTALLATION 5 TYPICAL INSTALLATION ILLUSTRATION 6 INSTALLATION STEPS 7 9 PROGRAMMING THE MW 40 DEMAND TIMER 10 11 SANITIZING PROCEDURES 11 WATER AND WATER CONDITIONING 12 13 HOW THE WATER SOFTENER...

Страница 4: ...8 WATER PRESSURE LIMITS min max psi 20 125 WATER TEMPERATURE LIMITS o F 40 120 WATER SUPPLY MINIMUM FLOW RATE gpm 3 REGENERATION CYCLE FLOW RATES gpm FILL flow to brine tank 3 BRINING 0 22 BRINE RINS...

Страница 5: ...In and out fittings included with the softener are 1 nominal copper sweat tubes To maintain full valve flow 1 pipes to and from the softener fittings are recommended You should maintain the same or l...

Страница 6: ...AUTOMATIC WATER SOFTENER TYPICAL SOLDERED COPPER or CPVC 6...

Страница 7: ...copper tubes or bypass valve to make sure they held securely in place 2 INSTALL THE BRINE TANK OVERFLOW FITTINGS Insert the rubber grommet into the diameter hole in the brine tank sidewall see page 9...

Страница 8: ...ameter hose and attach to the valve drain fitting Locate the other end of the hose at a suitable drain point floor drain sump laundry tub etc Check and comply with local codes IMPORTANT If a longer le...

Страница 9: ...y close the bypass valve and open the outlet valve SLOWLY open the inlet valve pausing several times to allow the softener to pressurize slowly E After about three minutes open a HOT water faucet for...

Страница 10: ...will not accept a change from the button or arrow you have pressed and you should use another To program the timer you will use the either SET UP or DOWN buttons SET PRESENT TIME OF DAY NOTE If the wo...

Страница 11: ...ot cause bacteria to form or grow However during shipping storage installing and operating bacteria could get into the softener For this reason sanitizing as follows is suggested when installing 1 Be...

Страница 12: ...minerals combine with soap to make a soap curd The curd greatly reduces the cleaning action of soap Precipitated hardness minerals form a crust on cooking utensils appliances and plumbing fixtures Eve...

Страница 13: ...with hardness minerals and they have to be cleaned This cleaning is called regeneration or recharge The Ultra demand timer automatically determines when regenerations occur Regeneration is started at...

Страница 14: ...AUTOMATIC WATER SOFTENER 14...

Страница 15: ...e water and salt Then salt will not dissolve in the water to make brine If the brine tank is full of salt it is hard to tell if you have a salt bridge Salt is loose on top but the bridge is under it T...

Страница 16: ...t order Lubricate the o ring seal with silicone grease and place in position Install and tighten the cap by hand only Do not over tighten and break the cap or housing SERVICE CHECKLIST NO SOFT WATER N...

Страница 17: ...l the next regeneration During regenerations the percentage increments upward NOTE Zero 0 shows until after the first regeneration begins after connecting to electrical power FLOW RATE GPM When using...

Страница 18: ...l power to the softener is interrupted the time display is blank but the timer keeps correct time for about 24 hours When power is restored you have to reset the present time only if the display is fl...

Страница 19: ...ate more frequent recharges however it will operate at 4000 grains per pound of salt or higher If you wish to turn the Salt Efficiency feature ON icon will show in display follow the instructions on t...

Страница 20: ...hr is set time displays are in military time 0100 1 00AM to 0000 midnight To change from the 12 hr setting do steps 1 3 4 5 and 7 GALLONS OR LITERS MEASURE All water flow rate and usage displays are...

Страница 21: ...RONIC SYSTEM PROFILE The Miracle Water demand timer ESP feature provides the homeowner or servicer with the latest in softener performance and electronic diagnostic technology ESP is the transmission...

Страница 22: ...ntative your name and complete address Inform the representative if you would like to speak with a technician and if you need a copy of the report or both The representative will connect you with a tr...

Страница 23: ...he top part of the display shows the cycle of regeneration and minutes of the cycle remaining If 2 cycle names are flashing the valve is in transition between the cycles A The 3 digits under WATER MAN...

Страница 24: ...diagnostics NOTE The face plate display must show a steady time not flashing 1 Press the RECHARGE button and hold in for 3 seconds RECHARGE NOW begins to flash as the softener enters the fill cycle o...

Страница 25: ...AUTOMATIC WATER SOFTENER WATER FLOW THROUGH VALVE 25...

Страница 26: ...AUTOMATIC WATER SOFTENER REPAIR PARTS 26...

Страница 27: ...e Cover also order following decal 450214 Decal Faceplate 15 7270232 Timer PWA 16 7252373 Transformer 17 7192785 Salt Cover MW 40 KEY NO PART NO DESCRIPTION OF PART 18 7163689 Vapor Barrier 19 7178626...

Страница 28: ...AUTOMATIC WATER SOFTENER REPAIR PARTS 29...

Страница 29: ...3 8 4 req 25 7094898 Turbine Support 26 7101548 Turbine 27 7248722 Sensor Housing Wiring Asm 28 0900060 O ring 29 7081201 Retainer Nozzle Venturi 30 Seal Nozzle Venturi KEY NO PART NUMBER DESCRIPTION...

Страница 30: ...AUTOMATIC WATER SOFTENER NOTES 30...

Страница 31: ...TAL CODE __________________________ ____________________________ SOFTENER MODEL NUMBER SERIAL NUMBER __________________________ ____________________________ DATE PURCHASED DATE PART FAILED MIRACLE WAT...

Отзывы: