..................................................AUTOMATIC WATER SOFTENER
MW-40
DEMAND TIMER FEATURES, SETTINGS, AND SERVICE, continued
RECHARGE NOW
Press and
hold
in the RECHARGE button
until
RECHARGE NOW
starts to flash in the time display
area. The softener begins an immediate regeneration,
and when over in about 2 hours, you will have a new
supply of soft water. Once started, you cannot cancel
this regeneration.
RECHARGE TONIGHT
Touch (
do not hold
) the RECHARGE button, and
RECHARGE TONIGHT
flashes in the time display
area. A regeneration will occur at the next preset
regeneration start time. If you decide to cancel this
regeneration, before it has started, touch the same
button once more.
VACATION NOTE ...........................................................................................................................
The MW-40 water softener regenerates only while water is used and softening capacity must be restored. For this
reason, the softener will not regenerate when you are away from home for extended periods.
feature: PROGRAM MEMORY .......................................................................................................
If electrical power to the softener is interrupted, the
time display is blank, but the timer keeps correct time
for about 24 hours. When power is restored, you have
to reset the present time
only if
the display is flashing.
All
other settings are maintained and never require
resetting unless a change is desired. If the time
is
flashing after a long power outage, the softener
continues to work as it should to provide you with soft
water. However, regenerations may occur at the
wrong time of day until you reset the timer to the
correct time of day, page 10.
setting: REGENERATION (STARTING) TIME, MAXIMUM DAYS BETWEEN REGENERATIONS,
EFFICIENCY MODE, HEAVY DUTY BACKWASH AND 97% FEATURE .....................................................
NOTE: Each of these settings has a factory set default value. The defaults are: Regeneration start time - 2:00AM;
Maximum days between regenerations - 0 (display shows dY -); Efficiency Mode – 97% – OFF; Heavy duty backwash
- OFF. The defaults suit most installations. However, depending on water supply quality, household peak water use
hours, etc., adjustment is available to meet specific needs. To make a change, read and do the following.
continued
18
Содержание MW-40
Страница 1: ...0 12 3 03456 3 7 8...
Страница 6: ...AUTOMATIC WATER SOFTENER TYPICAL SOLDERED COPPER or CPVC 6...
Страница 14: ...AUTOMATIC WATER SOFTENER 14...
Страница 25: ...AUTOMATIC WATER SOFTENER WATER FLOW THROUGH VALVE 25...
Страница 26: ...AUTOMATIC WATER SOFTENER REPAIR PARTS 26...
Страница 28: ...AUTOMATIC WATER SOFTENER REPAIR PARTS 29...
Страница 30: ...AUTOMATIC WATER SOFTENER NOTES 30...