Miracle Water MW-40 Скачать руководство пользователя страница 1

!"#$%&'()#*)+

!"#$%"$&'()%'()$')*$"+,-'%,

$."/-$0(-'12,$3'%,-

03456

3'%,-$7"8%,),-

!"#$%&'(%)*+,-.

Содержание MW-40

Страница 1: ...0 12 3 03456 3 7 8...

Страница 2: ...r replace any part which we find defective because of faulty materials and workmanship or corrosion You pay only freight to our factory and local labor charges ONE YEAR ON COMPLETE UNIT THREE YEARS ON...

Страница 3: ...G INSTALLATION 5 TYPICAL INSTALLATION ILLUSTRATION 6 INSTALLATION STEPS 7 9 PROGRAMMING THE MW 40 DEMAND TIMER 10 11 SANITIZING PROCEDURES 11 WATER AND WATER CONDITIONING 12 13 HOW THE WATER SOFTENER...

Страница 4: ...8 WATER PRESSURE LIMITS min max psi 20 125 WATER TEMPERATURE LIMITS o F 40 120 WATER SUPPLY MINIMUM FLOW RATE gpm 3 REGENERATION CYCLE FLOW RATES gpm FILL flow to brine tank 3 BRINING 0 22 BRINE RINS...

Страница 5: ...In and out fittings included with the softener are 1 nominal copper sweat tubes To maintain full valve flow 1 pipes to and from the softener fittings are recommended You should maintain the same or l...

Страница 6: ...AUTOMATIC WATER SOFTENER TYPICAL SOLDERED COPPER or CPVC 6...

Страница 7: ...copper tubes or bypass valve to make sure they held securely in place 2 INSTALL THE BRINE TANK OVERFLOW FITTINGS Insert the rubber grommet into the diameter hole in the brine tank sidewall see page 9...

Страница 8: ...ameter hose and attach to the valve drain fitting Locate the other end of the hose at a suitable drain point floor drain sump laundry tub etc Check and comply with local codes IMPORTANT If a longer le...

Страница 9: ...y close the bypass valve and open the outlet valve SLOWLY open the inlet valve pausing several times to allow the softener to pressurize slowly E After about three minutes open a HOT water faucet for...

Страница 10: ...will not accept a change from the button or arrow you have pressed and you should use another To program the timer you will use the either SET UP or DOWN buttons SET PRESENT TIME OF DAY NOTE If the wo...

Страница 11: ...ot cause bacteria to form or grow However during shipping storage installing and operating bacteria could get into the softener For this reason sanitizing as follows is suggested when installing 1 Be...

Страница 12: ...minerals combine with soap to make a soap curd The curd greatly reduces the cleaning action of soap Precipitated hardness minerals form a crust on cooking utensils appliances and plumbing fixtures Eve...

Страница 13: ...with hardness minerals and they have to be cleaned This cleaning is called regeneration or recharge The Ultra demand timer automatically determines when regenerations occur Regeneration is started at...

Страница 14: ...AUTOMATIC WATER SOFTENER 14...

Страница 15: ...e water and salt Then salt will not dissolve in the water to make brine If the brine tank is full of salt it is hard to tell if you have a salt bridge Salt is loose on top but the bridge is under it T...

Страница 16: ...t order Lubricate the o ring seal with silicone grease and place in position Install and tighten the cap by hand only Do not over tighten and break the cap or housing SERVICE CHECKLIST NO SOFT WATER N...

Страница 17: ...l the next regeneration During regenerations the percentage increments upward NOTE Zero 0 shows until after the first regeneration begins after connecting to electrical power FLOW RATE GPM When using...

Страница 18: ...l power to the softener is interrupted the time display is blank but the timer keeps correct time for about 24 hours When power is restored you have to reset the present time only if the display is fl...

Страница 19: ...ate more frequent recharges however it will operate at 4000 grains per pound of salt or higher If you wish to turn the Salt Efficiency feature ON icon will show in display follow the instructions on t...

Страница 20: ...hr is set time displays are in military time 0100 1 00AM to 0000 midnight To change from the 12 hr setting do steps 1 3 4 5 and 7 GALLONS OR LITERS MEASURE All water flow rate and usage displays are...

Страница 21: ...RONIC SYSTEM PROFILE The Miracle Water demand timer ESP feature provides the homeowner or servicer with the latest in softener performance and electronic diagnostic technology ESP is the transmission...

Страница 22: ...ntative your name and complete address Inform the representative if you would like to speak with a technician and if you need a copy of the report or both The representative will connect you with a tr...

Страница 23: ...he top part of the display shows the cycle of regeneration and minutes of the cycle remaining If 2 cycle names are flashing the valve is in transition between the cycles A The 3 digits under WATER MAN...

Страница 24: ...diagnostics NOTE The face plate display must show a steady time not flashing 1 Press the RECHARGE button and hold in for 3 seconds RECHARGE NOW begins to flash as the softener enters the fill cycle o...

Страница 25: ...AUTOMATIC WATER SOFTENER WATER FLOW THROUGH VALVE 25...

Страница 26: ...AUTOMATIC WATER SOFTENER REPAIR PARTS 26...

Страница 27: ...e Cover also order following decal 450214 Decal Faceplate 15 7270232 Timer PWA 16 7252373 Transformer 17 7192785 Salt Cover MW 40 KEY NO PART NO DESCRIPTION OF PART 18 7163689 Vapor Barrier 19 7178626...

Страница 28: ...AUTOMATIC WATER SOFTENER REPAIR PARTS 29...

Страница 29: ...3 8 4 req 25 7094898 Turbine Support 26 7101548 Turbine 27 7248722 Sensor Housing Wiring Asm 28 0900060 O ring 29 7081201 Retainer Nozzle Venturi 30 Seal Nozzle Venturi KEY NO PART NUMBER DESCRIPTION...

Страница 30: ...AUTOMATIC WATER SOFTENER NOTES 30...

Страница 31: ...TAL CODE __________________________ ____________________________ SOFTENER MODEL NUMBER SERIAL NUMBER __________________________ ____________________________ DATE PURCHASED DATE PART FAILED MIRACLE WAT...