Concealing Plate
Concealing Cap
Grubscrew
Control
Knobs
Concealing Ring
8. Refit or replace the filters and reassemble in
reverse order.
9. Restore the water supplies and check for
leaks.
Built in Models
1.
Isolate the hot and cold water supplies.
2.
Turn on the flow control knob to relieve water
pressure and to drain any residual water.
3.
Return the flow control knob to the off position
and carefully remove the concealing cap.
4.
Unscrew the grubscrew using a 2.5 mm
hexagonal key (supplied) and pull off the
control knob(s).
5.
Carefully unclip and remove the concealing
plate from the backplate.
Note!
Use a screwdriver in the cutout to assist
separation.
6.
Unscrew the filter caps with the ‘O’ key
(supplied) or a 12 mm hexagonal wrench and
remove the filters.
Note!
Use pliers to assist if necessary.
‘O’ key
Filter Cap
Filter
7.
Clean each of the filters under a jet of water to
remove any lodged particles.
8.
Refit
or replace
the filters and tighten the filter
caps.
Note!
Make sure that the seal is fitted correctly
and not damaged.
9.
Turn on the hot and cold water supplies and
check for leaks.
10.
Reassemble all other parts in reverse order.
Lubricants
Silicone based lubricants must only be used on
the rubber seals.
Caution!
Oil based or other lubricant types may
cause rapid deterioration of seals.
Cleaning
The chrome plated parts should be cleaned using
a mild washing up detergent or soap solution,
rinsed and then wiped dry with a soft cloth.
Warning!
Many household cleaners contain
abrasive and chemical substances, and should not
be used for cleaning plated or plastic fittings.
Do not
use descalents on this product.