![Mira GO 8.5 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/mira/go-8-5/go-8-5_installation-operation-maintenance-manual_1804952029.webp)
29
Malfunction
Cause
Remedy
Handset sprayplate
blocked.
Remove and clean (Refer to
Maintenance
in the I, O &
M guide for the fittings).
Other outlets being used
whilst showering, causing
water pressure to drop
below minimum required
to operate appliance.
Ensure other outlets e.g.
bath, washing machine or
dishwasher are not in use
whilst showering.
Water pressure below
minimum required for
appliance operation.
Ensure incoming water
supply stopcock and or
appliance isolating valve
turned fully on .
If fault still persists contact
Unable to select a
cool enough shower
during summer
months.
Due to the rise in water
mains supply temperature,
the power rating may be
too high.
Turn the TOP knob to
MEDIUM setting and re-
adjust temperature knob
until suitable temperature is
achieved.
Operation of
temperature knob has
little or no effect on
water temperature.
Remove Handset and clean
(Refer to
Maintenance
in
the I, O & M guide for the
fittings). If fault still persists
contact your installer.
Handset sprayplate
blocked.
(Continued)