![Mira GO 8.5 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/mira/go-8-5/go-8-5_installation-operation-maintenance-manual_1804952022.webp)
22
Heater Tank - Removal and Installation
Inlet Connector
Heater Tank
Clamp Bracket
Retaining Screws
Heater Tank
Retaining Screws
Outlet Connector
Solenoid Valve
Thermal Switch
Switch
Assembly
4.15.
Refit the components in reverse order. Make sure that the electrical wires are
installed in the correct positions.
5. Thermal Switch - Removal and Installation
Warning!
Make sure that the electrical supply is turned off at the mains and the
appropriate circuit fuse is removed. Mains electrical connections are exposed when the
cover is removed.
5.1.
Remove the three cover retaining screws, the cover and the service tunnel.
5.2.
Remove the hose from the outlet connector and loosen the connection to the inlet
connector assembly.
5.3.
To improve access to the top terminals of the tank the terminal block may be
loosened by removing the fixing screw.
Flow Valve
Clamp
Bracket
15mm
compression
straight connector
(not supplied)