Mira Enhance Скачать руководство пользователя страница 3

3

Section

1

Important Safety Information

1. WARNING!

1.1.

Products manufactured by Mira are precision engineered and should give
continuous superior and safe performance provided they are installed, operated
and maintained in accordance with the instructions and recommendations
given in this manual.

1.2.

Installation must be carried out by qualified personnel only.
Failure to comply with these safety instructions will cause risk to people and
equipment and may invalidate the guarantee.

Identified hazards are highlighted by the following symbols:

Danger from general causes:

Danger from electrical causes:

Instructions which if ignored could cause damage or impair the function of
the pump are highlighted by the word: 

ATTENTION

2. Caution!

2.1.

Read all of these instructions and retain this manual for later use.

2.2.

Pass on this manual in the event of change of ownership of the installation site.

2.3.

The plumbing installation must comply with the requirements of UK Water
Regulations/Bye-laws (Scotland), Building Regulations or any particular
regulations and practices, specified by the local water company or water
undertakers. The installation should be carried out by a plumber or contractor
who is registered, or is a member of, an association such as:

2.3.1.

Institute of Plumbing (IOP), throughout the UK.

2.3.2.

National Association of Plumbing, Heating and Mechanical Services
Contractors (NAPH & MSC), England and Wales.

2.3.3.

Scottish and Northern Ireland Plumbing Employers’ Federation
(SNIPEF), Scotland and Northern Ireland.

Содержание Enhance

Страница 1: ...1 Installation User Guide SHOWER PUMP THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER...

Страница 2: ...Power Supplies 7 Water Standards 8 Connections 8 4 Pack Contents Checklist Mira Enhance Shower Pump 9 Documentation 9 5 Installation Plumbing 10 Electrical 14 6 Commissioning Commissioning 17 7 Maint...

Страница 3: ...r impair the function of the pump are highlighted by the word ATTENTION 2 Caution 2 1 Read all of these instructions and retain this manual for later use 2 2 Passonthismanualintheeventofchangeofowners...

Страница 4: ...ed to the fixed wiring of the mains system Warning Do not use a plug and socket 2 5 TheinclusionofaResidualCurrentDevice RCD Earthtrip withatripcurrent of 30mA is recommended This may already be part...

Страница 5: ...ided ATTENTION Pipework on the outlet side of the pump that could be prone to airlocks can be fitted with a float type automatic air vent bottle vent at the highest point as showninFigure3 Thiswillens...

Страница 6: ...Refer to Figure 6 When the mixing valve is set to on and the momentaryactionswitchoperated thepumpwillrun Thepumpwillthenmaintainthe necessary flow rate in the outlet pipe and will continue to operat...

Страница 7: ...fset All dimensions are nominal and in millimetres ExternalDimensions Figure1 3 PowerSupplies 3 1 Single Phase 230V 50Hz fused supply through a 5A fused connection unit or equivalent refer to Figure 6...

Страница 8: ...all normal requirements and will minimize the deposition of scale in hard water areas 4 3 Delivery Rates See Pump Performance Graph Terminal fittings and associated pipe work will reduce this figure...

Страница 9: ...e appropriate boxes to familiarize yourself with the part names and to confirm that the parts are included Mira Enhance Shower Pump Inlet Adaptor Flow Switch Resilient Pad 2 Documentation 1 x Installa...

Страница 10: ...in the centre during the heating process before travelling up the vent 1 5 ATTENTION Water pumps can develop leaks and should therefore not be situatedwhereseepagemaygoundetectedorcausedamage Thepump...

Страница 11: ...ten the adapter 1 13 Install a short length of 15mm pipe at the pump outlet tighten the compressionjoint Pushtheflowswitchontothispipe endmarkedInletfirst ensuring that the flow switch is fitted verti...

Страница 12: ...g valve 25 mm A 30o to 60o 90o DHW Pump Other hot water services B A Key to symbols used in the system layouts Isolation Valve Mixing Valve Float Type Automatic Air Vent Bottle Valve Shower Handset Ch...

Страница 13: ...13 Cistern DHW Pump Optional Check Valve Other hot water services System Layout with High Level Pipework Figure 3 Other hot water services Pump Cistern DHW Unsuitable System Layout Figure 4...

Страница 14: ...hpoleshouldbeatleast3mm Acablewithaminimumcore area of 0 75mm2 should be used from the fuse to the pump 2 2 Remove the terminal cover single screw and connect the electrical supply and only if necessa...

Страница 15: ...andbondingclamps RefertoFigure7 Plasticpipesdonotrequirebonding Blue Brown Terminal Block Gland Nut Mains Cable Cable to Flow Switch FS E L N F S Brown Brown Blue Blue Brown Blue Connection Unit Fuse...

Страница 16: ...16 Outlet Inlet Pipe Bonding Details Figure 7...

Страница 17: ...t open for a short period of time to allow the air to be expelled from the system Turn off the shower and check the pump shower and the interconnecting pipework for leaks 1 5 If no water comes out of...

Страница 18: ...m Isolate power and water and check 1 1 2 Supply fuse mains supply and the fused connection unit 1 1 3 Free operation of the flow switch fitted externally in the outlet vertical pipe of the pump with...

Страница 19: ...Float type Automatic Air Vents are in general NOTadvisableforpumpinletpipework asanegativepump pressure will allow air to be sucked in through Automatic Air Vents The pressure at the desired vent pos...

Страница 20: ...20 1 Spare Parts Appendix 226 08 Resilient Pad 872 06 Flow Switch 226 08 872 06...

Страница 21: ...21 Notes...

Страница 22: ...22 Notes...

Страница 23: ...23 Notes...

Страница 24: ...omers in Republic of Ireland ModernPlantLtd Telephone Dublin 01 4591344 Mon to Fri 9am to 5pm Fax Dublin 01 4592329 24 hours Post Otter House NaasRoad Clondalkin Dublin22 Tovalidatetheguarantee please...

Отзывы: