44
Cartridge
Cover
Cover Retaining Screws
Plastic Pins
Cover 'O' Seal
Retaining Bush
'O' Seal
'O' Seal
'O' Seal
‘O’ Seal/Inlet Strainer Renewal
Should the ‘O’ seals require renewing then follow the procedure below:
Important!
Use only silicone based lubricants when reassembling.
1.
Follow the procedure detailed in
“Cartridge Renewal”: instructions 1.
to
5.
to
dismantle the shower control.
2.
Check the ‘O’ seals on the cartridge hot and cold inlets for any signs of damage and
renew if necessary.
3.
Remove the inlet strainers and check for damage, renew if necessary. Follow the
procedure detailed in
“Inlet Strainer Cleaning”: instructions 2.
to
4.
4.
Push the cartridge fully into the shower control body. Ensure the two plastic pins
locate in the brass body recess.
Important!
Ensure that the two inlet seals are well-lubricated and correctly located
before refitting the cartridge.
5.
Check the cartridge spindle ‘O’ seal (fitted in the cover) for signs of damage and
renew if necessary. Fit the spindle ‘O’ seal and retaining bush into the cover.
6.
Check the cover ‘O’ seal for signs of damage and renew if necessary.
7.
Follow the procedure detailed in
“Cartridge Renewal”: instructions 8.
to
14.
to
reassemble the shower control.
Figure 3
Inlet Strainer Unit
Содержание Combiforce 415