35
Maintenance and Service
5.8.1 Emptying the sweepings con-
tainer
Check the fill level of the sweeper's
container (Fig. 10/1) at regular intervals
(max. load capacity 25 kg) and empty
as necessary.
1. Switch the machine off and pull the
locking mechanism (Fig. 10/2) on the
sweeper's container (Fig. 10/1) up-
wards.
2. Pull the sweeper's container to the
rear out of the machine using the
handle (Fig. 10/4) and dispose of the
waste according to the applicable
environmental laws.
3. Reinstall the sweeper's container
and press it against the locking
mechanism until it audibly latches
into place.
5.8.2 Changing the seal
Check the seal (Fig. 10/3) weekly for
signs of wear and change it as neces-
sary.
1. Switch off the machine and pull the
locking mechanism (Fig. 10/2) on the
sweeper's container (Fig. 10/1) up-
wards.
2. Pull the sweepings container (Fig.
10/3) to the rear and out of the ma-
chine using the handle (Fig. 10/4).
3. Pull the seal on the sweeper's con-
tainer from the filter support frame.
Install a new seal.
4. Reinstall the sweeper's container
and press it against the locking
mechanism until it audibly latches
into place.
Содержание Kleen Sweep 25W
Страница 1: ...Instruction manual Kleen Sweep 25W 625821...
Страница 10: ...10 Safety Information Fig 1 1 7 6 2 4 3 5...
Страница 36: ...36 Maintenance and Service...