Codes that could be displayed on the charger are as follows:
“Bat” = The batteries are not detected. Voltage is below 2 volts,
The polarity could be reversed or batteries disconnected.
“Acd” = the charger programming set for wet lead acid batteries. (not an error)
“Gel” = charger programming set for gel batteries (not an error)
“E01” = maximum battery voltage has been reached.
“E02” = charger is overheating, faulty cooling fan or the cooling air to charger is obstructed.
“E03” = the batteries have exceeded the normal charge time. Possible battery sulfation has
occurred. Cycle the batteries several times (charge and discharge).
“SCt” = safety timer operation. This normally occurs after any allotted phase time period has
expired.
“Srt” = internal short circuit in charger. Replace the charger.
8.4 Battery Charger Error Codes
957745 Chargers Only
Page 25
Содержание E17BD
Страница 6: ...2 Technical Specifications E17BD E20 Page 6 ...
Страница 7: ...2 1 Dimensions E17BD E20 BD With a Straight Squeegee Page 7 ...
Страница 8: ...2 2 Dimensions E17 E20 With Curved Squeegee Page 8 ...
Страница 11: ...3 2 Minuteman System Maintenance I Page 11 ...
Страница 12: ...3 3 Minuteman System Maintenance II Page 12 ...
Страница 13: ...3 4 Minuteman System Maintenance S Page 13 ...
Страница 39: ...11 Squeegee Curved 11 Page 39 ...
Страница 40: ...11 Squeegee Curved 11 1 Page 40 ...
Страница 52: ...17 1 Solution Filter Version 1 17 1 Page 52 ...
Страница 64: ...20 Notes Page 64 ...