• Inspect unit upon receipt for any freight damages. Be sure

to keep all original packaging if return process is required.
If you discover any damages, please contact Minuteman
International.

• Check the machine for any obstructions in the fan or airflow

areas before plugging the unit in for operation.

• Set the machine in the desired orientation for operation.

• Ensure the switch is in the (OFF) position.

• Plug the power cord into a GFCI outlet.

• Do not use an extension cord.

• Do not use an adapter.

• Check GFCI protection by pushing “TEST” button. If operating

properly, “RESET” button will pop out. Remember to press
“RESET” button after testing to use machine.

• Do not plug more than a total of 12 amps into the GFCI outlet.

• Turn unit on
• When ‘daisy-chaining’ the machines, turn one unit on at a

time to prevent excessive current flood from starting multiple
units at one time.

• If red LED begins to flash, the unit has lost GFCI protection

and should be replaced immediately.

Содержание C43000-002H

Страница 1: ...ng and ventilation needs Our products are made to be durable and high performing The contents of this manual are based on the latest product information available at the time of publication We reserve...

Страница 2: ...process to bring you the best you can buy Please copy the form below fill out andcomment on how you found our catalog Thank you Name _____________________________________________________________ _ Tit...

Страница 3: ...Your Air Mover Provider PAGE 2 NOTES...

Страница 4: ...Your Air Mover Provider PAGE 3 NOTES...

Страница 5: ...is damaged or missing replace the power cord before further use Visually inspect the power cord before each use Ignoring these safety precautions may result in a fire or electrical shock Always use a...

Страница 6: ...nit thereby restricting airflow This may cause the unit to overheat Keep area around unit free and clear of any obstructions Save the shipping carton in case your air mover needs to be returned This u...

Страница 7: ...re the switch is in the OFF position Plug the power cord into a GFCI outlet Do not use an extension cord Do not use an adapter Check GFCI protection by pushing TEST button If operating properly RESET...

Страница 8: ...amaged Plug unit into proper outlet Replace switch Reset breaker Replace power cord or replace cord end Replace motor Air mover will not operate on all speeds Switch is worn Capacitor on motor is worn...