22

  

IRIS                                                                                                                                

   Default  setting

   AUTO  

Two  Iris  modes:  AUTO/MANUAL  
  

ZOOM  LIMIT

                                                                                                         Default  setting

X18  

Zoom  limit  will  show  different  limit  according  to  different  cameras  
  

ZOOM  SPEED

                                                                                                         Default  setting

5  

Zoom  speed  has  1  to  7  level  zoom  speed  and  will  show  different  times  according  to  different  cameras.  

  
ZOOM  LABLE                                                                                                  

      Default  setting

OFF  

Two  options  for  zoom:  ON/off  

  
in  <NEXT>  press  Iris  

OPEN

,  the  screen  displays  second  page  of  the  camera  parameter  setting  menu  

page  .  

  

Note:  VIDEO  FREEZE  function  depends  on  whether  the  camera  has  this  function,  it  can  be  set  if  the  camera  

has  this  feature;;  and  it  can  not  be  set  if  camera  do  not  have  this  feature.  

  

WHITEBALANCE  will  be  different  according  to  the  different  brands,  so  the  factory  value  varies  due  to  the  
camera.  

  

WHITEBALANCE

                                                                                       Default  setting

   AUTO  

White  balance  can  be  selected  the      AUTO

INDOOR

OUTDOOR

ONEPUSH

ATW  types,  different  camera  

will  be  different.  
  

BACKLIGHT

                                                                                                      Default  setting

OFF  

Two  select  models  for  back  light:  ON

OFF  

  
DAY/NIGHT

                                                                                                         Default  setting

AUTO  

Three  models  for  day/night  selection:  AUTO

DAY

NIGHT  

  

VIDEO  FREEZE

                                                                                                Default  setting

OFF  

Two  select  models  for  video  freeze:  ON/OFF  
  

14.3.3  Pan/tilt  parameter  setting  menu     
               <PAN/TILT>  
               press  Iris  OPEN,  the  screen  displays  pan/tilt  parameter  setting  menu  page  

  

Содержание uv83

Страница 1: ...Video Conference Camera User Manual...

Страница 2: ...e installed where exposed to rain and moisture Do not open the camera box as to prevent the danger of electric shock Installation and servicing should only be done by qualified service personnel It mu...

Страница 3: ...CAMERA INTERFACE EXPLANATION 8 CONNECTION 9 CAMERA INTERFACE EXPLANATION 10 RS485 RS422 INTERFACE PIN ASSIGNMENT 11 SVIDEO INTERFACE PIN ASSIGNMENT 12 INSTALLATION 13 OPERATION 14 MENU CONTROL 15 MAIN...

Страница 4: ...he camera by seizing the camera head Don t rotate camera head by hand otherwise mechanical trouble will occur 1 This series item must put on the smooth desk or platform and it can not be installed sla...

Страница 5: ...81mm All setting of camera and pan tilt zoom can be remote high speed communication controlled 256 presets User can preset the pan tilt zoom for 256 presets P D protocol 256 presets VISCA protocol 16...

Страница 6: ...ipod screw hole 7 Installation Orientation Hole 8 Bottom dial Switch 9 RS485 and RS422 control interface 10 RS232 VISCA OUT output port 11 RS232 VISCA OUT input port 12 SVIDEO signal output 13 AV inte...

Страница 7: ...cus focus length near from far Auto focus the camera focus mode is auto Manual focus the camera focus mode is manual 6 Controlled Camera address selection F1 Camera Address No 1 F2 Camera Address No 2...

Страница 8: ...djust the brighter background when under highlight this is can help to prevent the image become too bright because of too highlight of the background and the object will not be recognizable so the cam...

Страница 9: ...N Normal Working mode ON Software update mode OFF Note SW1 dial switch position1 2 3 are to be set the receiving address P control Protocol address setting SW1 Switch Setting Address SW1 1 SW1 2 SW1 3...

Страница 10: ...deo signal Standard definition video signal SVIDEO SVIDEO SD video signal VISCA out connecting cable not attached Communication cable to connect the interfaces of two cameras Power supply interface DC...

Страница 11: ...DSR 7 7 RTS 8 NC 8 CTS 9 RI Camera Windows DB 25 1 DTR 1 FG 2 DSR 2 TXD 3 TXD 3 RXD 4 GND 4 RTS 5 RXD 5 CTS 6 GND 6 DSR 7 7 GND 8 NC 20 DTR VISCA IN Definition Camera Mini DIN 1 DTR 1 DTR 2 DSR 2 DSR...

Страница 12: ...ideo conference camera s RX RX Then connecting the interface of controller equipment RX IN RX IN to the camera s interface of TX TX Then can control the camera after adjusting the protocol Baud rate a...

Страница 13: ...are available for users upon the on site situation on desktop on terminal equipment on tripod on hoisting bracket Steps to install in ceiling Step 1 install the upper base Drill three holes on the ce...

Страница 14: ...nstall the lower base Stamp insulation pads on the installation holes and make sure the holes are aligned Put the pins in locating hole and then fix the base at the baseboard of the camera with 1 4 in...

Страница 15: ...ot install the camera obliquely Batteries installation Open the battery cover install the batteries and close the cover Be attention to the anode and cathode Notice Change batteries if the remoter doe...

Страница 16: ...reset positions via remote controller Instruction 1 In this instruction press the key means a click other than a long press and a special note will be given if a long press for more than one second is...

Страница 17: ...e action of focus continues and stops as soon as the key is released 5 BLC Setting BLC ON Open BLC BLC OFF Close BLC 6 Presets setting To set a preset position the users should press the SET PRESET ke...

Страница 18: ...cusing and default iris data The users can control the pan tilt zoom manual focus presets setting and running of the camera via RS 232 command The control of preset position includes the following two...

Страница 19: ...range from 0 to 1x20 YYYY for pan position range from 0XF6A0 0x0960 ZZZZ for tilt position range from 0XFB50 0x04B0 Zoom out 81 01 04 07 3z FF Zoom in 81 01 04 07 2z FF Stop 81 01 04 07 00 FF z zoom s...

Страница 20: ...Setting command Auto exposure 81 01 04 39 00 FF Manual iris 81 01 04 39 0B FF Iris 81 01 04 0B 02 FF Iris 81 01 04 0B 03 FF Iris control Iris stop 81 01 04 0B 00 FF Menu Setting Function Setting comm...

Страница 21: ...his series conference camera is according to P D control protocol By calling the number 95 preset commands to open menu by calling 94 preset commands to exit menu other control Settings please refer t...

Страница 22: ...address if the current protocol is PELCO P or PELCO D and the others which are corresponding to the P D protocol will show the corresponding protocol address PTZ responds control commands based on the...

Страница 23: ...ction it can be set if the camera has this feature and it can not be set if camera do not have this feature WHITEBALANCE will be different according to the different brands so the factory value varies...

Страница 24: ...er setting menu bar all restore to the factory settings RESET PAN TILT Reset pan tilt parameter pan tilt parameter setting menu bar all restore to the factory settings Note pan tilt reset will not mak...

Страница 25: ...are all on OFF Check video and TV wire is connected correctly Abnormal display of image Check the video connecting wires is well and other connecting sockets and camera flat wires are well The camera...

Страница 26: ...e S Video output 4pin mini DIN Controller Signal Interface 8 core mini DIN Controller Signal Interface Start bit 1 Data bit 8 Stop bit 1 Baud Ratio 1200 2400 4800 9600bps Power interface HEC3800 Power...

Страница 27: ...nd transmission 8 00 FF Check sum XOR 1 7 bytes Instruction command BYTE VALUE FUNCTION 1 A0 STX start transmission 2 00 to FF Address 3 Data byte 1 4 Data byte 2 5 Data byte 3 6 Data byte 4 7 AF ETX...

Страница 28: ...pendix D control protocol command format BYTE VALUE FUNCTION 1 FF STX start transmission 2 01 TO 1F Address 3 Data byte 1 4 Data byte 2 5 Data byte 3 6 Data byte 4 7 00 FF Checksum add byte 2 3 4 5 6...

Страница 29: ...se digital zoom 81 set or run No 81 preset auto low lux switch function 82 set or run No 82 preset Open low lux shift B W image 83 set or run No 83 preset Close low lux shift color image 84 set or run...

Отзывы: