In the section below, the operation of the machine is explained.
Two dual-action hydraulic outlet with ISO 7241-1 standard compliant are
required for operating the discharge cover.
If your tractor has only a single set of ports, then the manuel diverter or
electric selector valve option shoul be ordered!
To activate the hydraulic system of the discharge unit, connect the
hydraulic hoses (Figure 13.1) to into the couplers on the tractor normally with
the system unpressurized.
To ensure that the system is unpressurized before disconnecting the hoses,
move the valve control levers to their most extreme positions when the tractor’
s power switched off, so any eventual pressure from hydraulic system is
allowed to return to the tractor oil tank.
The maximum pressure in the hydraulic system is 210 bar. NEVER EXCEED the
maximum pressure in the hydraulic system!
● Before starting hydraulic connecting Please see section 1.6!
Figure 13 - The locations of the hydraulic hoses on the mixer feeder.
4.2- Working With The Minos Vertical Mixer-Feeder
(only for implements driven by a P.T.O Shaft)