![MINOLTA-QMS PagePro 4100 Series Скачать руководство пользователя страница 105](http://html.mh-extra.com/html/minolta-qms/pagepro-4100-series/pagepro-4100-series_service-manual_1803611105.webp)
90
5
AD
JUS
T
M
E
N
T
5. ADJUSTMENT
5-1. Adjustment of Image Registration
After the Mechanical Control Board (PWB-A) is replaced, print an image sample. If the
starting position of the image (registration gap (d)=4mm) in the sub-scanning direction is
not suitable, adjust the gap by following one of the procedures described below.
1
Remove the right cover so that VR1 of PWB-A can be adjusted.
2
Turning VR1 on PWB-A in the clockwise direction makes the gap (d) greater and
turning it in the counter-clockwise direction makes the gap (d) smaller.
Adjustment by Voltage
1
Touch the positive and negative terminals of the tester to VR1 and frame GND respec-
tively with power turned on.
2
Adjust VR1 until the tester reads between 2.4 to 2.54 VDC.
VR1
d
4mm
Содержание PagePro 4100 Series
Страница 2: ......
Страница 12: ...ix WARNING LABEL ...
Страница 124: ...U Usage Environment 1 V Video Interface Engine I F 33 W White spots 103 White Black lines and bands 105 ...
Страница 125: ...Second Paper Cassette Unit 4100GN Standard 4100W 4110W 4100E Option ...
Страница 126: ...PagePro 4100W 4110W 4100W 4110W ...