6. Use a #2 phillips screw driver to remove the plastic strain relief holding the power cord to the side of the extrusion (image
4). Save this for reuse with the cable connector assembly.
7. Route the new power cable connector assembly behind the the lift motor.
8. Replace the plastic strain relief onto the new cable jacket and secure with the strain relief screw.
9. Place the heat shrink sleeves over each lead from the new cable connector assembly, and connect each of the terminals to
the board as shown in image 3.
10. Apply heat to the heat shrink tubing to seal the connections. Be careful not to burn any of the adjacent components or
wires.
11. Reassemble the left motor cover, making sure there are no wires pinched at any point during reassembly. Reference the
image 2 for proper hardware placement.
Image 3
Image 4
Remove the
strain relief
Do not remove
Cut heat shrink