background image

7

RPM

CFM

N.W. G.W.

C.F.

13.5"

120
120
120

Fan Size  Speed Volts Amps  Watts

Low 

Medium

High

4.023'

0.218

0.284
0.363

25.1

33.8
43.2

666
975

1256

605.7

889.69

1122.09

SPECIFICATIONS

These are typical readings. Your actual fan may vary. They 
do not include amps and wattage used by the light(s).

For any additional information about your 

 Minka Aire  Ceiling fan, please write to;  

R

1151 W. Bradford Court, Corona, CA 92882 

For Customer Assistance Call: 1-800-307-3267

7.38 

kgs

9.26

kgs

Содержание Anywhere F307

Страница 1: ...INSTRUCTION MANUAL WARRANTY CERTIFICATE ANYWHERE TM BY U S Patent s Pending ...

Страница 2: ... 2017 Minka Lighting Inc Manual design and all elements of manual design are protected by United States Federal and or State Law including Patents Trademark and or Copyright Laws ...

Страница 3: ...a Aire ceiling fan excluding wall controls and electrical components to the original purchaser or user The warranty is voided with the use of any non Minka Aire electrical devices E g wall controls or electrical dimmer switches etc The warranty is void once the original purchaser or user ceases to own the fan or the fan is moved from its original point of installation The warranty is void with the...

Страница 4: ...y claim Replacement is subject to availability of the same model If the model is unavailable it will be replaced by one of equal value This is a limited warranty the original purchaser or user is responsible for the cost of removal and reinstallation of repaired or replacement product To obtain the name of the Minka Aire authorized dealer nearest you call the Minka Aire customer care department at...

Страница 5: ...OUR FAN TROUBLESHOOTING SPECIFICATIONS 1 2 3 4 5 6 7 1151 W Bradford Court Corona CA 92882 For Customer Assistance Call 1 800 307 3267 SAFETY RULES PACKAGE CONTENTS HANGING THE FAN OPERATING YOUR FAN UL LISTED E320317 R ...

Страница 6: ...ease use a qualified electrican WARNING WARNING The stud wood post or beam on which the fan will be installed must be securely mounted and capable of supporting at least 50 pounds 22 7 kilograms The stud or wood beam must be supported directly by the building structure WARNING WARNING Support fan Directly Building Structure To avoid personal injury damage to the fan and possible electrical shock a...

Страница 7: ...Discard product if the attachment plug is damaged WARNING WARNING To reduce the risk of fire DO NOT use of any extension cord WARNING WARNING To avoid personal injury or damage to the fan and other items be cautions when working around or cleaning the fan WARNING WARNING To reduce the risk of personal injury use only parts provided with this fan The use of parts OTHER than those provided with this...

Страница 8: ... location this fan must be connected to a supply circuit that is protected by a Ground Fault Circuit interrupter GFCI to reduce the risk of personal injury electrical shock or death 6 After install installation is complete check that all connections are absolutely secure NOTE NOTE The important safeguards and instructions appearing in this manual are not meant to cover all possible conditions and ...

Страница 9: ... 2 1 Fan motor assembly A Mounting hardware 10x 1 5 Mounting screws 6PCs B Rubber cover C Pull chain fob PACKAGE CONTENTS Unpack your fan and check the contents You should have the following items A B C ...

Страница 10: ...w fan The use of other parts hardware or components not supplied by Minka Aire with the fan will void the Minka Aire Warranty Turn off circuit breakers to current fixture from breaker panel Fig 1 WARNING WARNING Failure to disconnect power supply prior to installation may result in serious injury Remove the wall bracket from fan assembly by remove two thumbscrews You can keep the thumbscrews for l...

Страница 11: ...ATE CONCRETE WALL INSTALLATION ALTERNATE CONCRETE WALL INSTALLATION Use all 6 mounting 1 4 6 5mm holes when installing wall bracket on a concrete wall The 3 16in 5mm concrete wall anchors necessary for this type of installation are NOT provided and must be purchased separately Make sure that concrete wall anchors can support a tatol of 80 lbs WARNING WARNING It is very important that you must use ...

Страница 12: ...s This work must be done only by a qualified electrician using sopper wire only Fig 6 The three prong plug is installed with a fuse that is a vital safety device A filament inside the fuse is designed to melt and cut the circuit if the current gets too high This prevents damage to your fan and the person using it and dtops the power cord from overheating to the point where it could catch fire 8 If...

Страница 13: ...OLES STUD WALL OUTLET WALL BRACKET MOUNTING HOLES BLOWN FUSE FUSE 5 AMPS 125V FUSE COVER PLUG FAN ASSEMBLY WALL BRACKET HOOKS SLOTS THUMB SCREWS FAN ASSEMBLY WALL OUTLET FIG 3 FIG 4 FIG 5 FIG 6 MOUNTING SCREWS ...

Страница 14: ...Take off the 3 P wire connector and remove the setscrew on power cord and then CUT OFF CUT OFF the power cord and take out the power cord from fan assembly Fig 8 3 Make the 3 pin wire connections from power wire to the fan assembly Attach the rubber cover into the hole on fan body Fig 8 4 Fit the power wire through the hole on center of the back cover Install the back cover onto the fan assembly w...

Страница 15: ...IG 9 FIG 7 POWER CORD RUBBER COVER CUT OFF POWER CORD SETSCREW 3 PIN WIRE CONNECTORS POWER WIRE BACK COVER MOUNTING SCREWS BACK COVER FAN ASSEMBLY POWER WIRE BACK COVER MOUNTING SCREWS BACK COVER FAN ASSEMBLY ...

Страница 16: ...LLATION Use all 6 mounting 1 4 6 5mm holes when installing wall bracket on a concrete wall The 3 16in 5mm concrete wall anchors necessary for this type of installation are NOT provided and must be purchased separately Make sure that concrete wall anchors can support a tatol of 80 lbs WARNING WARNING It is very important that you must use the proper hardware when installing the wall bracket as this...

Страница 17: ...slots in the fan assembly and that the fan assembly is stable 10 Replace the thumbscrews at bottom of fan assembly be sure to securely tighten thumbscrews Fig 12 WARNING WARNING To reduce the risk of fire electric shock or personal injury apply polyurethane adhesive polyurethane adhesive not included on the back side between the fan body and the wall after you are finish to install Fig 13 FIG 10 P...

Страница 18: ...FIG 11 FIG 12 FIG 13 FAN ASSEMBLY WIRE NUTS FAN ASSEMBLY WALL BRACKET HOOKS THUMB SCREWS SLOTS POLYURETHANE ADHESIVE WALL ...

Страница 19: ...the operation of the fan Fig 14 A The pull chain controls the fan speed as follows 1 pull High 2 pulls Medium 3 pulls Low and 4 pulls Off B Rotating Switch This switvh is used to regulate the oscillating operation C Screw Knob Loosen Screw Knob before rotating the fan head back to a desired head angle Fig 15 FIG 14 A B C FIG 15 C ...

Страница 20: ...finish of your fan Use only a soft lint free cloth and soapy water 3 If you need to disassemble the fan for any reason such as cleaning please take off the two guard setscrews and to secure the screws after cleaning the blades Fig 16 4 Use a lint free lightly damp cloth or duster to remove dust from the blades 5 There is no need to oil your fan The motor has permanently lubricated bearings WARNING...

Страница 21: ...ections to the fan Remove back cover and check wire connections SOLUTION SYMPTOM Fan Sounds Noisy Make sure all screws on fan motor assembly and fan guards are snug Make sure the safety guard are securely in place Allow a 24 hour breaking in period Most noises associated with a new fan disappear during this time SOLUTION ...

Страница 22: ...5 1256 605 7 889 69 1122 09 SPECIFICATIONS These are typical readings Your actual fan may vary They do not include amps and wattage used by the light s For any additional information about your Minka Aire Ceiling fan please write to R 1151 W Bradford Court Corona CA 92882 For Customer Assistance Call 1 800 307 3267 7 38 kgs 9 26 kgs ...

Отзывы: