![Minipack-Torre RP40 Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/minipack-torre/rp40/rp40_installation-operation-and-maintenance-manual_1802448022.webp)
20
Chapter 6. Machine adjustment and setting up
EN
Through button (S) it is possible to look through the variables of the selected program, while through buttons (2) and (3)
the memorized values can be modified. These buttons (2) and (3) act by one digit at a time, but if they are held down for
more than a second, the value will rapidly increase or decrease.
To validate modifications, press button (S) until the number of the program appears on the display.
The fan delay time after sealing can be modified; there is not a LED indicating this variable which is shown with an “
r
” on
the left display, whereas the two remaining digits will indicate the set up time.
At the end of all variables to be adjusted, the display will show the code of the program just chosen (for example P01).
Note: If the hood is closed during the programming phase, the machine will not work.
Once all adjustments have been made, the machine is ready to start working.
TABLE OF PARAMETERS ACCORDING TO PROGRAMMES
Variable P01
(sealing only)
P02, 03, 04, 05, 06, 07, 08, 09, 10
(sealing and shrinking)
Sealing time
(values expressed in seconds)
Min. = 0,0
Max. = 3,0
Default = 1,3
Min. = 0,0
Max. = 3,0
Default = 1,3
Fan delay time after sealing
(values expressed in seconds)
not settable
Min. = 0,0
Max. = 1,0
Default = 0,0
Shrinking time
(values expressed in seconds)
not settable
Min. = 0,0
Max. = 10,0
Default = 2,5
Heat chamber temperature
the indicated value will correspond to:
0 = 0° (the heating element is switched off)
1 … 150 = 100° … 398°C (2°C each point)
not settable
Min. = 0
Max. = 150
Default = 120
CYCLE COUNTER
When the machine is in the PROGRAMS SELECTION mode, the display will show the programme that is being run (e.g.
“P01”).
In this mode, press button (P) to activate the “cycle counter” function”.
The display indicates the number of cycles since the machine was switched on.
Then, press and hold buttons (2), (3) and (S) simultaneously for 3 seconds to activate the “totalizer” function.
The display indicates a figure corresponding to the total number of cycles performed by the machine, expressed in
thousands.
Starting from the right, the numbers that appear on the display indicate:
1
st
number = thousands of cycles
2
nd
number = tens of thousands of cycles
3
rd
number = hundreds of thousands of cycles
Press button (2) again and the display indicates a number corresponding to the units.
The display indicates a figure corresponding to the total number of cycles performed by the machine, expressed in units.
Starting from the right, the numbers that appear on the display indicate:
1
st
number = single cycles
2
nd
number = tens of cycles
3
rd
number = hundreds of cycles
Press button (2) again to return to the “cycle counter” function
Finally, press button (P) to return to normal operation (the display shows the current programme).
APPROXIMATE TABLE OF MACHINE CICLE ADJUSTEMENT
Shrinking time
Pause time
Heat chamber temperature
(value indicated on the display)
6” 6”
5” 7”
4” 8”
3” 9”
2” 10”