FILM LOOSENING
[mm]
56 56CS 56MPE 56MPS
Adjusts the distance by which the film and product must be retracted before sealing, in
mm (advisable when processing products over 200 mm in height). Values: 0 ÷ 250.
BELTS APPROACHING
56 56CS
This function enables the operator to activate the system used to move the belts (IN)
and (OUT) closer to sealing area when processing smaller pieces. Values: ON / OFF.
The function can be ON only if it is enabled in OPTIONALS.
PUNCH
56 56CS 56MPE 56MPS
This function activates the pneumatic perforator (OPTIONAL). Values: ON / OFF.
The function can be ON only if it is enabled in OPTIONALS.
MARK READOUT
56 56CS 56MPE 56MPS
This function enables a dedicated photocell (OPTIONAL) that reads the markers on
opaque or coloured films.
The function can be ON only if it is enabled in OPTIONALS.
UNWINDER DELAY
[s]
56 56CS 56MPE 56MPS
This function enables the operator to decrease the film tension on the triangles,
delaying the moment when the unwinder starts running (advisable with products up to
100 mm in height). Values: 0 ÷ 3.
The next 3 screens allow data to be entered relating to the manual settings to be
applied to the machine, so that every time this program is loaded, that memorised
settings can be applied.
NUMBER OF MICROPUNCHES
56 56CS 56MPE 56MPS
Enter the number of micro-punches (MF) to be positioned on the machine (see
paragraph 5.4 PHASE 6).
FILM REEL POSITION
56 56CS 56MPE 56MPS
Enter the film reel position with reference to the millimetre scale (X1) (see paragraph
5.4 PHASE 6).
FILM DRIVING ROLL POSITION
56 56CS 56MPE 56MPS
Enter the position of the return roller (R5) with reference to the millimetre scale (X2)
(see paragraph 5.4 PHASE 6).
REWINDER DELAY
[s]
56 56CS 56MPE 56MPS
This enables the operator to decrease the film tension on the rewinder rollers, delaying
the moment when the rewinder stops running. Values: 0 ÷ 1.
The next 4 screens allow data to be entered relating to the manual settings to be
applied to the any combined tunnel, so that every time this program is loaded, that
memorised settings can be applied.
SPEED
56 56CS 56MPE 56MPS
Enter the tunnel's conveyor belt speed.
INFEED T.
56 56CS 56MPE 56MPS
Enter the temperature of the tunnel's infeed area.
OUTFEED T.
56 56CS 56MPE 56MPS
Enter the temperature of the tunnel's outfeed area.
DEFLECTORS POSITION
56 56CS 56MPE 56MPS
Click on the
▲ and ▼ arrows to "graphically" represent the position of the tunnel deflectors.
Note: This screen changes depending on whether the coupled tunnel is Tunnel 50, Tunnel 50
Twin, or Tunnel 70. There is only one temperature in Tunnel 50 (it does not change between
infeed and outfeed) and there are 2 deflectors instead of 4.