6) 3x(500ms ON,500ms OFF) + 3 sec OFF repeatedly: Hardware OFF delay (time
between the off pulse is sent and cut off of the output voltage) set by the
UPS_HARDOFF_TOUT, entering deep sleep
Status of Battery LED:
-Fast blinking: incorrect configuration of the cell numbers, or wrong connections on
the balancing header.
-Toggle every 1 sec: Battery is being charged
-Steady ON: Battery is fully charged (100%)
-Steady OFF: (together with main LED's 500msec ON, 2.5 sec OFF:) System is
running on battery
All LEDS OFF:
Unit is in Deep sleep mode consuming very little power. MCU is not powered. Can be
waked up by shorting J8 or if input voltage is present.
Setting Power plans under Windows Operating Systems
:
Ex:Vista,Win7
-Right click on the battery icon from the traybar then choose power options from the
context menu. Alternatively you can choose Power Options also from Control Panel
Items.
-Select/create a power plan or modify existing ones.
-In the “Change Advanced power settings” section the critical and low battery levels
and actions can be also modified