background image

KT60558-1G

Tightening torque (N·m)

(N·m)

(kgf·cm

M5

8.4

86

M8

42.1

430

M10

90.0

918

M12

150

1531

Sec 4: Measurement Preparations

(1) Wiring
   Connect the dedicated cable (CAC-176B-*M) with the transmitter to be used. 
   For more information, see the transmitter (OPT-563B) instruction manual.
(2) Calibration
   Adjust the zero and calibrate the output when operating with no load.
   For more information, see the transmitter (OPT-563B) instruction manual.
   A positive torque output is generated when the rotor is twisted counterclockwise.
   The output polarity can be altered by the settings for the transmitter (OPT-563B).
(3) Test running
   Test run the equipment by operating at low speed. Confirm the absence of abnormal output, noise, 
   overheating, or vibration before starting measurement.

Sec 5: Maintenance and Inspections

This equipment transmits signals optically. This means the signal may not be transmitted 
or received correctly if the photo emitter or photoreceptor is obscured by soot or other 
contaminants. If necessary

 keep the surfaces of the photo emitter and photoreceptor clean

by ethanol or other solvent.

Sec 6: Precautions

(1)

This equipment transmits signals optically. While ambient fluorescent lights should 
present no problems, infrared light from sunlight or incandescent lights may cause 
malfunctions. Use a protective cover to shield against outside light if the equipment 
is used in locations where sunlight or incandescent lights are present.

(2)

The antenna stator conveys a current to transmit the input voltage.
Do not allow it to come into contact with covers in the vicinity or other metal objects.

(3)

Two signal output connectors are located on the left and right of the stator.
These are provided to allow the cable to be connected to either side to suit 
the installation configuration. Make sure that only one connector is used at any given time.
The signal cannot be output from both connectors simultaneously.

(4)

This is a rotating part. Keep a protective cover fitted at all times to prevent 
material from flying out.

(5)

Vibration may result if the equipment balance is upset after attaching the coupling. 
Adjust the dynamic balance for the equipment as a whole after combining the torque 
transducer with the coupling and other devices.

(6)

Impact loads or vibrations will subject the torque transducer to dynamic loads consisting 
of the static load multiplied by the acceleration. Make sure the value taking into account the 
acceleration does not exceed the rated capacity of the torque transducer.

(7)

Install safety devices to prevent damage if there is a likelihood of excessive loads 
acting on the torque transducer.

(8)

Make sure the installation location is sufficiently strong.

(9)

Use the equipment at ambient temperatures within the compensation temperature range.

(10) Avoid locations subject to sudden temperature fluctuations or direct heat sources.
(11) Check the protection rating. Make sure the equipment is used under 

Nominal bolt

diameter

MinebeaMitsumi Inc. Sensing Device Business Unit

6

Содержание TMHS-NM Series

Страница 1: ...㻷㼀㻢㻜㻡㻡㻤㻙㻝㻳 䚷 TORQUE TRANSDUCER TMHS NM for Torque Transducer Instruction Manual Sensing Device Business Unit MinebeaMitsumi Inc ...

Страница 2: ...This equipment is capable of measuring both static and dynamic torque by using a thin flange bearing free torque transducer combining a torque detector flange calibrated by attaching a strain gauge and an optical transformer that acquires a signal optically without making contact with the rotor Features include high precision high stiffness improved fatigue resistance and improved long term consis...

Страница 3: ...d to the metal rim of the torque transducer flange 䞉Ø104 mm max for TMHS 100NM to 300NM 䞉Ø111 mm max for TMHS 500NM and 1KNM 䞉Ø153 mm max for TMHS 2KNM and 3KNM 2 Distance from torque transducer flange edge face 䞉 At least 8 mm for A type mounting flange configuration diameter extends to rotor 䞉 At least 15 mm for B type mounting flange configuration diameter extends to stator 3 Distance from torq...

Страница 4: ...o the specified tightening torque Please be careful when mounting in case of the damage to the transmission coil䠄Bakelite bobbin䠅on the rotor periphery After mounting peel off the green tape protecting the photo emitter ᅗ䠍 Mounting bolt size 100䡚300NM M8 500NM 1KNM M10 2KNM 3KNM M12 100NM䡚500NM 1KNM䡚3KNM Rotor stator alignment face Gap 6 Opposing flange Hex socket head bolts x8 Coil Stator antenna...

Страница 5: ... and spring washers After securing the stator fully tighten the bolts on the separated antenna Malfunctions may occur if the bolts on the antenna are not properly tightened 䚷䚷3 4 Mounting precautions 1 Select fixing bolts with a JIS B 1051 strength classification of at least 12 9 2 Make sure the thread engagement length of the bolts is not less than the nominal bolt diameter 3 Make sure the stator...

Страница 6: ...ight or incandescent lights are present 2 The antenna stator conveys a current to transmit the input voltage Do not allow it to come into contact with covers in the vicinity or other metal objects 3 Two signal output connectors are located on the left and right of the stator These are provided to allow the cable to be connected to either side to suit the installation configuration Make sure that o...

Страница 7: ...KT60558 1G conditions free of condensation MinebeaMitsumi Inc Sensing Device Business Unit 7 ...

Страница 8: ......

Страница 9: ...e Product Sales Management 1 1 1 Katase Fujisawa shi Kanagawa ken 251 8531 Japan Tel 81 466 23 2681 Fax 81 466 22 7191 Sensing Device Business Unit FUJISAWA PLANT 1 1 1 Katase Fujisawa shi Kanagawa ken 251 8531 Japan Tel 81 466 22 7151 Fax 81 466 22 1701 KARUIZAWA PLANT 4106 73 Miyota Miyota machi Kitasaku gun Nagano ken 389 0293 Japan Tel 81 267 31 1309 Fax 81 267 31 1353 HOMEPAGE ADDRESS http ww...

Отзывы: