![Minebea Intec Puro LargeCount EF-LT P1 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/minebea-intec/puro-largecount-ef-lt-p1/puro-largecount-ef-lt-p1_operating-instructions-manual_1801213023.webp)
The initialization of the Counting application is only possible on scale 1. The initialization
is carried out with the internal scale resolution.
5.2.3.1.1
Initialization with known reference quantity
This initialization is only carried out when the weight values are stable.
-
Initialization (see Chapter
)
-
Initialization of a negative sample (see Chapter
These initializations are possible even if a sample weight has already been calculated.
The entry can be corrected using the
key, which is used to delete the last digit of the
entry in each case.
If there is no load on the weighing pan (< 2 d), the error message [REF.ERR] is displayed
for around 2 seconds in the "PW" display.
Piece Weight
5.2.3.1.1.1 Initializing
5.2.3.1.1.2 Initialization via the removal of parts
If the removal of parts from a container is required:
Proceed with step 2 in Chapter
.
5.2.3.1.2
Initialization according to known sample weight
5.2.3.2
Performing Counting (without check weighing)
Automatic reference optimization (see Chapter
).
If a sample weight is initialized, it is displayed in the "PW" display.
1.
Place some parts on the weighing pan.
2.
Enter the known number of parts on the weighing pan via the keypad (only whole
number values) or using a scanner.
The entered value is displayed in the "Count" display.
3.
Briefly press the
key.
The newly calculated sample weight is displayed in the "PW" display, and the
actually calculated number of parts is displayed in the "Count" display.
1.
Place a full container on the scale.
2.
Briefly press the
key (tare container).
3.
Remove some parts from the container.
Now a negative weight value is displayed in the "Weight" display.
1.
Enter the desired sample weight via the keypad or using a scanner.
The entered value is displayed in the "Count" display.
2.
Briefly press the
key.
The newly adopted sample weight is displayed in the "PW" display, and the
actually calculated number of parts is displayed in the "Count" display.
5 Operating
Compact scale Puro® LargeCount
Minebea Intec
EN-21