10. SPM | 10.4 - System data | 131
SPM address Data type
R/W
Function
X112
BOOL
W
Zero device.
X113
BOOL
W
Tare device
X114
BOOL
W
Reset the tare of the device
X115
BOOL
W
Start the test mode
X116
BOOL
W
Finish the test mode
X117
BOOL
W
Reset the power fail signal
X118
BOOL
W
Set fixed tare weight D31 as tare
X119
BOOL
W
Store the current gross weight in the preset tare memory
(D31)
X121
BOOL
W
Reset error B19 = 0.
B16
SINT
R
Exponent
Number of decimal places
Example: 1.23 is displayed
Exponent: 2
B17
SINT
R
Weight unit 1 = g, 2 = kg, 3 = t, 4 = lb
B18
SINT
R
Verification scale interval (for multi-interval/multi-range
= d1 or e1)
B19
BYTE
R
Last weighing point error, see Chapter
.
B20
BYTE
R
Higher byte of product code (0x52)
B21
BYTE
R
Lower byte of product code (0x15)
B22
BYTE
R
Major part of version number (1.0)
B23
BYTE
R
Minor part of version number (1.0)
D6
UDINT
R
Serial number (board number)
D8
DINT
R
Current gross weight
D9
DINT
R
Current net weight
D10
DINT
R
Current tare weight