![Mindra HK-D07-230-NE1 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/mindra/hk-d07-230-ne1/hk-d07-230-ne1_user-manual_1800758009.webp)
Type 2 AC EV charger Instructions-
V1.1.0
3
IEC 60664-1
:
2007
Equipment and control equipment components in low-voltage systems - Part 1:
General rules
DIN SPEC70121
:
2014
Electric vehicle-DC charging system and electric vehicle control system
combined charging system charging digital communication
DIN SPEC70122
:
2018
Digital communication of the charging system combined by EV DC charging
system and EV control system
4. Environmental Conditions
No.
Item
Technical targets
Unit
Remark
Working
Transportation
Storage
1
Temperature
-30
℃
~
55
℃
-40
℃
~
70
℃
-40
℃
~
70
℃
℃
2
Humidity
5
~
95
/
5
~
95
%
Condensation
free
3
Altitude
≤2500
/
≤2500
m
4
Cooling method
Natural Cooling
-
5. Electric Characteristics
5.1 Input characteristics
No.
Item
Technical requirements
Unit
Remark
1
Rated input voltage
7kW
230
VAC
L+N+PE
22kW
400
3P+N+PE
2
Rated input current
7kW
32
A
L+N+PE
22kW
32
3P+N+PE
3
AC input voltage range
7kW
184~276
VAC
Systematical
input
voltage
22kW
320~480
VAC
4
AC input frequency range
45~65
Hz
Rated
frequency
50Hz/60Hz