5
5.4 EMC Characteristics
No.
Item
Technical Requirements
Unit
Remark
1
Electrostatic discharge immunity
Level 3
-
2
Radiofrequency electromagnetic radiation immunity
Level 3
-
3
Power frequency magnetic field immunity test
Level 5
-
4
Electrical fast transient pulse group disturbance
immunity
Level 4
-
5
Surge (impact) immunity
Level 4
-
6
Test for conduction disturbance immunity of RF
field induction
Level 3
-
7
Voltage sag, short interruption immunity
Level 3
-
8
Harmonic current emission limit test
Grade A
-
9
Voltage fluctuation and scintillation test
Grade A
-
10
Power terminal conduction disturbance test
Grade A
-
11
Signal port conduct disturbance check
Grade A
-
12
Protects keyless entry system from radiation
harassment inspection
Grade A
-
13
Shell port radiation harassment inspection
Grade A
-
5.5 Safety features
No.
Item
Technical requirements
Unit
Remark
1
Insulation
resistance
Input-Earth
≥10
MΩ
500VDC
Output-Earth
≥10
MΩ
500VDC
2
Dielectric
strength
Input-Earth
≤10
mA
2.8kVDC
Output-Earth
≤10
mA
2.8kVDC
3
Impulse
withstand
voltage
Input-Earth
No breakdown and insulation damage
-
lightning
impulse±6KV
Output-Earth