1 2
Connections
XP-AC-E10U series connections
Connect the power input leads, an external line fuse and a DC motor to terminal
board TB501 as shown in Figure 5 (page 13).
Motor
Minarik drives supply motor voltage from A1 and A2 terminals. It is assumed
throughout this manual that, when A1 is positive with respect to A2 , the motor will
rotate clockwise (CW) while looking at the output shaft protruding from the front of the
motor. If this is opposite of the desired rotation, simply reverse the wiring of A1 and
A2 with each other.
Connect a DC motor to terminals A1 and A2 as shown in Figure 5 (page 13).
Ensure
that the motor voltage and current ratings are consistent with the drive’s output
voltage and current.
Power input
Connect the AC line power leads to terminals L1 and L2, or to a single-throw, double-
pole master power switch (recommended).