28
Problem
Possible
Causes
Suggested
Solutions
Troubleshooting
1. Line fuses are the
wrong size.
2. Motor cable or
armature is shorted
to ground.
3. Nuisance tripping
caused by a
combination of
ambient conditions
and high-current
spikes
(i.e. reversing).
1. MIN OUT and
MAX OUT
settings are too
high.
1. Check that line
fuses are the
correct size.
2. Check motor cable
and armature for
shorts.
3. Add a blower to
cool the drive
components;
increase FWD TQ
and REV TQ
settings.
1. Recalibrate MIN
OUT and MAX
OUT.
Line fuse blows
Motor runs too fast
at maximum speed
setting