6
Installation
Heat sinking
Model PCMXP10-115AC requires an additional heat sink when the
continuous armature current is above 5 ADC. Use Minarik part
number 223-0159. All other chassis drives have sufficient heat
sinking in their basic configurations. Use a thermally conductive
heat sink compound (such as Dow Corning
®
340 Heat Sink
Compound) between the drive chassis and heat sink surface for
optimum heat transfer.
Line fusing
Protect all PCMXP Series drives with AC line fuses. Use fast acting
AC line fuses rated for 250 volts, and approximately
150% to 200% of the maximum armature current. Fuse only the
“hot” side of the AC line (L1) if using 115 VAC line voltage.
See the chart below for recommended line fuse sizes:
Line Fuse Chart
Maximum Armature
AC Line Fuse
Current (DC Amps)
Rating (AC Amps)
0.5
1
0.8
1.5
1.5
3
2.6
5
3.5
8
5.0
10
7.6
15
10