Calibration
Figure 11. Typical IR COMP and TORQUE Settings
(settings may vary by application)
5.
Set the speed potentiometer or reference signal to
maximum speed. The motor should remain stopped.
6.
Slowly rotate the TORQUE trimpot clockwise (CW) until
the ammeter reads 120% of maximum motor armature
current.
7.
Set the speed adjust potentiometer or reference signal to
zero speed.
8.
Remove power from the drive.
9.
Remove the lock from the motor shaft.
10. Remove the ammeter in series with the motor armature.