26
MM-PCM Series
The MAX SPD setting determines the maximum motor speed when the
speed adjust potentiometer or input voltage or current signal is set for
maximum speed.
To calibrate MAX SPD:
1. Set the speed adjust potentiometer or input voltage or current
signal for maximum speed.
2 . Adjust MAX SPD until the desired maximum speed is reached.
Note: Check the MIN out and MAX SPD adjustments after recalibrating
to verify that the motor runs at the desired minimum and maximum
speed.
Maximum Speed (MAX SPD)
The MIN OUT setting determines the minimum motor speed when the
speed adjust potentiometer or input voltage or current signal is set for
minimum speed. It is factory set for zero speed.
To calibrate the MIN OUT:
1. Set the speed adjust potentiometer or input voltage or current
signal for minimum speed.
2. Adjust MIN OUT until the desired minimum speed is reached or
is just at the threshold of rotation.
Minimum Speed (MIN OUT)