THE GUARD IS FITTED TO THIS
APPLIANCE TO REDUCE THE RISK
OF FIRE OR INJURY FROM BURNS
AND NO PART OF IT SHOULD BE
REMOVED.
Storage
1. Always close the gas valve of the gas cylinder after use or in case of a disturbance.
2. Disconnect the regulator from the gas cylinder valve.
3. Check the tightness of the gas valve for damage. If you suspect damage, have it changed
by your gas dealer.
4. Never store gas cylinders underground or in places without adequate air ventilation.
5. There is no limitation on the storage of appliances indoors provided that the cylinder is removed
from the appliance; and
6. Storage of an appliance indoors with the cylinder attached is only permitted if the size of the
cylinder complies with AS/NZS 1596; otherwise cylinders must be stored outdoors in a
well-ventilated area and out of reach of children.
WHEN LIGHTING HEATER, KEEP
FACE AWAY FROM EMITTER
GUARD.
1.
2.
3.
6.
5.
4.
Variable Control knob
TO TURN ON THE HEATER
The pilot burner is a very
small burner below the
large heater burner.
To light the heater
, turn
the control knob to the
pilot position and keep
the control knob
depressed so gas can
ÀRZWRWKHSLORWEXUQHU
.
This can take 1 to 2
minutes.
Activate the igniter button
repeatedly until you see
WKHEOXHÀDPHRIWKHSLORW
through the viewing
holes.
7KHSLORWÀDPH
can be difficult to see in
direct sunlight.
PILOT
PILOT
Keep the control knob
depressed for 30
seconds after the pilot
burner is alight to
establish the pilot flame,
then release the knob
and check the pilot
remains alight.
Turn knob to the HI
position to light the
heater burner.
If the pilot will not stay
alight, reset the tip over
switch by tilting the
heater 45°, then return
the heater to upright.
Lighting Tip: If the Pilot flame drops out
repeatedly while lighting, try turning the knob
to HI immediately after the pilot has ignited.
Operation and Storage
Page 6
Содержание 0229110