Mimosa 0229110 Скачать руководство пользователя страница 5

610mm

for JDS04

610mm

CEILING

WA

L

L

480 mm

480 mm

How to locate the heater with Zero Clearance

This heater can be located with zero clearance provided the heater does not transfer excessive heat to the 
surrounding walls. Ensure to locate your heater as described below to prevent heat damage or fire on 
surrounding structures.

The heater is for outdoor use only. Always ensure that adequate fresh air 
ventilation is provided.
Always maintain proper clearance to combustible materials, i.e. top 480mm 
and sides 480mm minimum.

Any enclosure in which the appliance is used shall comply with one of 

the following:

An enclosure with walls on all sides, but at least one permanent opening 

at ground level and no overhead cover.

Within a partial enclosure that includes an overhead cover and no more than two walls.

Within a partial enclosure that includes an overhead cover and more than two walls, 

the following shall apply:

   at least 25% of the total wall area is completely open, and

   at least 30% of the remaining wall area is open and unrestricted.

In the case of balconies, at least 20% of the total wall area shall be and remain open 

and unrestricted.

Never operate heater in an explosive atmosphere like in areas where
petrol or other flammable liquids or vapors are stored.
This appliance shall only be used in an above ground open-air situation 
with natural ventilation, without stagnant areas, where gas leakage and 
products of combustion are rapidly dispersed by wind and natural convection.
This appliance shall be used only in an outdoor area and shall not be used 
in a building, garage or any other enclosed area unless the enclosure meets 
the requirements outlined in this instruction manual.

Heater must be placed on level firm ground.

Corner location.

Zero clearance

to rear corner.

Wall location.

Zero Clearance

to rear wall.

Incorrect location.

Don’t face the heater

towards a corner or wall.

Incorrect location.

Don’t face the heater so

heat is projected along a wall.

Heater Stand and Location

Page 2

Содержание 0229110

Страница 1: ...OUTDOOR GAS AREA HEATER DIRECTIONAL BLACK Provides warmth and ambiance for outdoor settings AGA Gas Certified Important Please retain these instructions for future use 0229110 0229110 SAH006...

Страница 2: ...Gas Leak Test...

Страница 3: ...2 Gas Requirements Page 5 Leakage Test Page 5 Operation and Storage Page 6 Cleaning and Care Page 7 Parts and Specifications Page 7 Assembly Parts and Procedures Page 8 Assembly Steps Page 9 Pilot Se...

Страница 4: ...Control compartment burner and circulation air passageways of the heater must be kept clean More frequent cleaning may be required as necessary The gas cylinder should be turned off when the heater is...

Страница 5: ...owing shall apply at least 25 of the total wall area is completely open and at least 30 of the remaining wall area is open and unrestricted In the case of balconies at least 20 of the total wall area...

Страница 6: ...OOR AREAS The following figures are diagrammatical representations of outdoor areas as described above Rectangular areas have been used in these figures the same principles apply to any other shaped a...

Страница 7: ...total wall area 30 percent or more in total of the remaining wall area is open and unrestricted Open side at least 25 of total wall area 30 percent or more in total of the remaining wall area is open...

Страница 8: ...to shipment A complete gas tightness check must be performed due to possible mishandling in shipment or excessive pressure being applied to the heater Make a soap solution of one part liquid detergen...

Страница 9: ...HEN LIGHTING HEATER KEEP FACE AWAY FROM EMITTER GUARD 1 2 3 6 5 4 Variable Control knob TO TURN ON THE HEATER The pilot burner is a very small burner below the large heater burner To light the heater...

Страница 10: ...sive Remove debris from the burner to keep it clean and safe for use Cover the burner unit with the optional protective cover when the heater is not in use Flame screen guard Burner assembly Base of c...

Страница 11: ...cm including stand With AGA CE and CSA certificates Gas inlet fitting 1 4 inverted flare type with internal O ring seal 4pcs Self Taping Screws for burner head and tank housing body Hose and regulato...

Страница 12: ...he section GAS LEAK TEST 2 6 Put the gas cylinder into the tank housing then close the door 2 5 Thoroughly check the gas connections for gas leakage If you identify a leak and it cannot be stopped dis...

Страница 13: ...spider webs or nests Blow air through the pilot burner tube and through the air holes at the base of the pilot tube to clear the pilot burner of dead moths or bugs Don t poke wire or drills into the p...

Страница 14: ...cylinder valve UUDQJH UH OOLQJ RU H FKDQJH RI your LPG cylinder Service the pilot burner as shown in this manual Follow the lighting steps again Turn knob to PILOT then press and hold the knob in for...

Страница 15: ...Consumer Law or Consumer Guarantees Act 1993 NZ You are entitled to replacement or refund for a major failure and to compensation for other reasonably foreseeable loss or damage You are also entitled...

Отзывы: