610mm
for JDS04
610mm
CEILING
WA
L
L
480 mm
480 mm
How to locate the heater with Zero Clearance
This heater can be located with zero clearance provided the heater does not transfer excessive heat to the
surrounding walls. Ensure to locate your heater as described below to prevent heat damage or fire on
surrounding structures.
The heater is for outdoor use only. Always ensure that adequate fresh air
ventilation is provided.
Always maintain proper clearance to combustible materials, i.e. top 480mm
and sides 480mm minimum.
Any enclosure in which the appliance is used shall comply with one of
the following:
An enclosure with walls on all sides, but at least one permanent opening
at ground level and no overhead cover.
Within a partial enclosure that includes an overhead cover and no more than two walls.
Within a partial enclosure that includes an overhead cover and more than two walls,
the following shall apply:
at least 25% of the total wall area is completely open, and
at least 30% of the remaining wall area is open and unrestricted.
In the case of balconies, at least 20% of the total wall area shall be and remain open
and unrestricted.
Never operate heater in an explosive atmosphere like in areas where
petrol or other flammable liquids or vapors are stored.
This appliance shall only be used in an above ground open-air situation
with natural ventilation, without stagnant areas, where gas leakage and
products of combustion are rapidly dispersed by wind and natural convection.
This appliance shall be used only in an outdoor area and shall not be used
in a building, garage or any other enclosed area unless the enclosure meets
the requirements outlined in this instruction manual.
Heater must be placed on level firm ground.
Corner location.
Zero clearance
to rear corner.
Wall location.
Zero Clearance
to rear wall.
Incorrect location.
Don’t face the heater
towards a corner or wall.
Incorrect location.
Don’t face the heater so
heat is projected along a wall.
Heater Stand and Location
Page 2
Содержание 0229110
Страница 2: ...Gas Leak Test...