3. Maintenance Procedure
17
3
Open the front cover.
4
Clean the wiper and bracket.
•
5
Press the [ENTER] key once cleaning is complete.
• “Cap Cleaning Completed (Next)[ENT]” appears on the display.
6
Clean the cap rubber.
•
7
Once cleaning is complete, close the cover, then press the [ENTER] key.
• “Fill the Liquid. Exit Next [ENT]” appears on the display.
8
Fill the cap with maintenance liquid.
• Use a syringe to draw up some maintenance liquid and fill it until it almost overflows from the cap.
9
Close the front cover, then press the [ENTER] key.
• Print nozzle washing starts. The elapsed time is displayed on the display. Nozzle washing takes
approximately one minute.
• Cleaning is performed automatically once print nozzle washing has ended.
• “Fill the Liquid. Exit Next [ENT]” appears on the display.
10
Open the front cover.
11
Fill the cap with maintenance liquid.
• Use a syringe to draw up some maintenance liquid and fill it until it almost overflows from the cap.
12
Close the front cover, then press the [ENTER] key.
• Pump tube (ink discharge channel below the cap) washing starts.